Calculating the nominal current
Calculate the nominal current according to the ambient temperature as follows:
6.3
Starting Up the V-273 with the C-413 Controller
NOTICE
Unexpected motion!
The V-273 can perform unexpected motion after the controller is switched on or rebooted.
Unexpected motion can lead to damage due to collisions.
Before
connecting the V-273, check whether the controller is configured for automatic
execution of the reference move or the autozero procedure; see user manual of the
controller.
INFORMATION
The type of the connection on the C-413 controller and the parameter settings of the C-413
determine the identifiers that are to be used to command the V-273. Assignment with the
default settings of the C-413 controller:
Motor cable connected to the
Motor & Sensor 1
socket using the V901B0030 adapter and -
if present - force sensor connected to the
Motor & Sensor 2
socket: V-273 is commanded
as axis 1; the force sensor can be read out as input signal channel 3 and must be assigned
to axis 1 via the Input Channel for Force Feedback parameter (ID 0x07000400).
Motor cable connected to the
Motor & Sensor 2
socket using the V901B0030 adapter and -
if present - force sensor connected to the
Motor & Sensor 1
socket: V-273 is commanded
as axis 2; the force sensor can be read out as input signal channel 1 and must be assigned
to axis 2 via the Input Channel for Force Feedback parameter (ID 0x07000400).
Requirements
You have read and understood the general notes on startup and operation (p. 25).
You have read and understood the user manual of the controller.