PI V-273 VC Скачать руководство пользователя страница 27

 

 

5 Installation 

V-273 VC Linear Actuator 

MP155E 

Version: 1.1.4 

23 

Attaching the V-273 to the fixed part of the mounting 

1.

 

Align the linear actuator or surface so that the corresponding mounting holes in linear 

actuator and surface overlap. 

2.

 

Turn the screws into the mounting holes in the bottom of the underlying surface. 
Maximum screw-in depth: 5 mm 
Maximum torque: 2.6 Nm 

3.

 

Check that the V-273 is fixed firmly to the surface. 

  

 

5.4

 

Connecting the V-273 to the Controller 

 

INFORMATION 

 

The V901B0030 adapter is adapted at the factory to the V-273 to achieve optimal positioning 

accuracy. Replacing the adapter or the V-273 leads to an incorrect positioning and may even 

lead to oscillations of the servo loop. 

 

When connecting the V-273, pay attention to the assignment of the adapter to the V-273, 

which is specified on the label of the adapter. 

  

Requirements 

 

You have read and understood the general notes on installation (p. 17). 

 

The controller is switched off, i.e., 

not

 connected to the power supply 

Tools and accessories 

 

V901B0030 adapter D-sub 15 (m/f), included in the scope of delivery (p. 11) 

 

Motor cable D-sub 15 (m/f), to be ordered separately 

 

C-413.2xx controller (p. 11) 

Connecting the V-273 to the controller 

1.

 

Connect the D-sub 15-pole (f) connector of the adapter to the 

Motor &Sensor

 socket of 

the controller. 

2.

 

Connect the connector of the motor cable to the D-sub 15-pole (f) socket of the 

adapter. 

3.

 

Connect the socket of the motor cable to the D-sub 15-pole panel plug (m) of the linear 

actuator. 

4.

 

Secure the adapter and motor cable with the integrated screws against unintentional 

disconnection from each other or from the controller and the linear actuator. 

5.

 

When the linear actuator has a force sensor with a separate D-sub 15 (m) connector: 

Connect the force sensor to the 

Motor & Sensor

 socket of the C-413 that is still free. 

Содержание V-273 VC

Страница 1: ...info pi ws www pi ws MP155E V 273 VC Linear Actuator User Manual Version 1 1 4 Date 22 06 2020 This document describes the following products V 273 440 PIMag voice coil linear actuator 20 mm 6 N line...

Страница 2: ...com en about pi patents 2020 Physik Instrumente PI GmbH Co KG Karlsruhe Germany The text photographs and drawings in this manual are protected by copyright With regard thereto Physik Instrumente PI Gm...

Страница 3: ...iew 7 3 2 1 Overview 7 3 2 2 Product Details 8 3 2 3 Product Labeling 10 3 3 Scope of Delivery 11 3 4 Suitable Controllers 11 3 5 Technical Features 12 3 5 1 Linear Encoder 12 3 5 2 Reference Switch 1...

Страница 4: ...Cleaning the V 273 32 8 Troubleshooting 33 9 Customer Service 35 10 Technical Data 37 10 1 Specifications 37 10 1 1 Data Table 37 10 1 2 Maximum Ratings 38 10 1 3 Ambient Conditions and Classificatio...

Страница 5: ...reader has a fundamental understanding of basic servo systems as well as motion control concepts and applicable safety procedures The latest versions of the user manuals are available for download p...

Страница 6: ...g signs attached to the product referring to detailed information in this manual 1 3 Definition of Terms Term Explanation VC linear actuator VC linear drive VC Voice Coil The feed is generated by the...

Страница 7: ...fter the controller is switched on referencing must be done before absolute target positions can be commanded and reached 1 4 Figures For better understandability the colors proportions and degree of...

Страница 8: ...r Actuator 3 Click the corresponding product to open the product detail page 4 Click Downloads The manuals are shown under Documentation 5 Click the desired manual and fill out the inquiry form The do...

Страница 9: ...ch a failure would present severe risks to human beings or the environment The intended use of the V 273 is only possible when installed and in conjunction with a suitable controller p 11 The controll...

Страница 10: ...relevant information provided by the manufacturer Always work according to the complete user manual If your user manual is incomplete and is therefore missing important information damage to equipment...

Страница 11: ...Overview Two standard versions of the V 273 linear actuator are available They differ with regard to the force sensor and therefore the dimensions Model Dimension Force sensor present V 273 440 200 m...

Страница 12: ...ide rail 2 Housing 3 Connector for motor cable panel plug Sub D 15 x Positive direction of motion Figure 3 Front side of the linear actuator here V 273 441 1 Cable exit of the force sensor 2 Exchangea...

Страница 13: ...b D 15 2 Connector for controller connector Sub D 15 Figure 5 Force sensor 1 M3 threaded bolt for screwing the contact part onto the force sensor Figure 6 Transport safeguard on the side of the linear...

Страница 14: ...refer to the model 116003601 Serial number example individual for each V 273 Meaning of each position from the left 1 internal information 2 and 3 year of manufacture 4 to 9 consecutive number Manufa...

Страница 15: ...ub 15 m f adapter for the connection of the motor cable MP162EK Short instructions in printed form 3 4 Suitable Controllers The V 273 must be connected to a suitable controller The following controlle...

Страница 16: ...at indicates whether the linear actuator is on the positive or negative side of the reference switch See the controller user manual and or associated software manuals for the commands that make use of...

Страница 17: ...rmation on the ID chip recognition see the manual of the controller used INFORMATION The V901B0030 adapter must not be used if a controller other than a PI controller is to be used In addition the fol...

Страница 18: ......

Страница 19: ...The V 273 is delivered with a transport safeguard attached Figure 8 Transport safeguard on the side of the linear actuator V 273 44x hole pattern and the transport safeguard are identical for the V 2...

Страница 20: ...MP155E V 273 VC Linear Actuator 4 Remove the transport safeguard a Loosen and remove both M3 screws b Remove the bracket 5 Keep all packaging materials and the transport safeguard in case the product...

Страница 21: ...zone is marked CAUTION Risk of cuts and crushing The V 273 linear actuator can generate high forces at high velocities When a contact part with a small contact surface is installed on the runner of t...

Страница 22: ...the V 273 s housing Take appropriate precautions for storage and transport NOTICE Damage to magnetically sensitive objects The magnets in the V 273 can damage parts susceptible to magnetic influences...

Страница 23: ...art of the Force Sensor on the V 273 441 INFORMATION The mechanical coupling of the runner to a surface is achieved using the contact part of the force sensor A contact part made of aluminum and plast...

Страница 24: ...age the V 273 Pay attention to the maximum screw in depth for the mounting holes p 40 Only use screws of the correct length for the respective mounting holes NOTICE Distorting the V 273 when mounted o...

Страница 25: ...for affixing the movable part of the mounting to the runner Figure 10 V 273 440 Mounting holes for mounting the V 273 onto a surface identical for V 273 441 Figure 11 V 273 441 Ideally the contact pa...

Страница 26: ...es as well as the length of the screws used are matched so that the maximum screw in depth in the V 273 is adhered to p 40 The flatness of the surface is 20 m For applications with large temperature c...

Страница 27: ...ed on the label of the adapter Requirements You have read and understood the general notes on installation p 17 The controller is switched off i e not connected to the power supply Tools and accessori...

Страница 28: ......

Страница 29: ...onnected or switched off Make sure that people with heart pacemakers and electronic implants do not have access to the V 273 Make sure that the danger zone is marked NOTICE Overheating caused by unfav...

Страница 30: ...which the V 273 is specified Operate the V 273 only when the operating voltage is properly connected see Pin Assignment p 43 NOTICE Undesired displacement due to lack of self locking The drive of the...

Страница 31: ...at the end of the travel range Determine the maximum velocity for your application NOTICE Damage to the V 273 and the load due to oscillation The optimum values of the servo control parameters of the...

Страница 32: ...ways approached from the same side Recommended controllers from PI fulfill this requirement with their automatic direction detection for reference moves to the reference switch INFORMATION The force s...

Страница 33: ...t are to be used to command the V 273 Assignment with the default settings of the C 413 controller Motor cable connected to the Motor Sensor 1 socket using the V901B0030 adapter and if present force s...

Страница 34: ...1 via the cable of the force sensor You have installed the linear actuator so that no force is applied to the contact part of the force sensor when the controller is switched on or rebooted p 20 Start...

Страница 35: ...aring the V 273 for Transport NOTICE Mechanical overload from incorrect handling An impermissible mechanical load on the V 273 due to transportation without a transport safeguard and incorrect handlin...

Страница 36: ...tuator 7 3 Cleaning the V 273 Requirements You have disconnected the linear actuator from the controller Cleaning the linear actuator When necessary clean the surface of the linear actuator with a clo...

Страница 37: ...273 Increased wear Warped housing Excessive lateral forces on the runner Excessive velocity Travel with maximum force to the hard stop Mount the V 273 on a flat surface The recommended flatness of the...

Страница 38: ......

Страница 39: ...mation Product and serial numbers of all products in the system Firmware version of the controller if applicable Version of the driver or the software if applicable Operating system on the PC if appli...

Страница 40: ......

Страница 41: ...tion 10 1 nm Max Minimum incremental motion 100 nm Typ Linearity error closed loop 1 Typ Repeatability 0 5 m Typ Velocity 100 mm s Max Force sensor resolution optional 1 mN Max Smallest force step opt...

Страница 42: ...Miscellaneous Operating temperature range 10 to 60 C Material Aluminum Mass 660 790 g 5 Cable length V 273 441 Force sensor cable 1 m Motor sensor connector V 273 440 D sub 15 m V 273 441 2 D sub 15 m...

Страница 43: ...mperatures up to 31 C Decreasing linearly to 50 relative humidity at 40 C Storage temperature 20 C to 60 C Transport temperature 20 C to 60 C Overvoltage category II Protection class I Degree of pollu...

Страница 44: ...on 1 1 4 MP155E V 273 VC Linear Actuator 10 2 Dimensions 10 2 1 V 273 440 Dimensions in mm Note that a comma is used in the drawings instead of a decimal point Figure 12 Dimensions of the V 273 440 ru...

Страница 45: ...imensions in mm Note that a comma is used in the drawings instead of a decimal point Figure 13 Dimensions of the V 273 441 here without contact part of the force sensor runner in reference position 1...

Страница 46: ...10 Technical Data 42 Version 1 1 4 MP155E V 273 VC Linear Actuator Figure 14 Dimensions of the V 273 441 here with contact part of the force sensor runner in reference position...

Страница 47: ...1 Reference TTL output 2 Motor Input current 3 AGND GND 4 VDD 5 V Input 5 6 7 SIN TTL output 8 COS TTL output 9 Motor Input current 10 AGND GND 11 AGND GND 12 13 Reference TTL output 14 SIN TTL outpu...

Страница 48: ...ler side Pin Signal Pin Signal 1 Reference 1 2 Motor 2 Motor 3 AGND 3 AGND 4 VDD 5V 4 VDD 5V 5 5 6 6 CS_EEPROM_1 7 SIN 7 SPI_MOSI 8 COS 8 SPI_MISO 9 Motor 9 Motor 10 AGND 10 AGND 11 AGND 11 AGND 12 12...

Страница 49: ...Connector D sub 15 connector m panel plug Pin Function Direction 1 2 3 GND GND 4 VDD 5 V Input 5 6 SPI_CS_EEPROM TTL input 7 SPI_MOSI TTL input 8 SPI_MISO TTL output 9 10 11 12 13 14 SPI_CLK TTL inpu...

Страница 50: ......

Страница 51: ...rnational national and local rules and regulations In order to fulfil its responsibility as the product manufacturer Physik Instrumente PI GmbH Co KG undertakes environmentally correct disposal of all...

Страница 52: ......

Страница 53: ...73 an EU Declaration of Conformity has been issued in accordance with the following European directives EMC Directive RoHS Directive The applied standards certifying the conformity are listed below EM...

Отзывы: