6 Startup and Operation
V-273 VC Linear Actuator
MP155E
Version: 1.1.4
25
In this Chapter
General Notes on Startup and Operation .................................................................................... 25
Temperature Dependency of the Nominal Current: Calculating the Nominal Current............... 28
Starting Up the V-273 with the C-413 Controller ........................................................................ 29
6.1
General Notes on Startup and Operation
The V-273 is started and operated with the PIMag® C-413 motion controller from PI.
DANGER
Strong magnetic fields affect heart pacemakers!
The V-273 contains permanent magnets that could impair the function of heart pacemakers
and electronic implants.
The permanent magnet's magnetic fields are also effective when the
linear actuator is not connected or switched off.
Make sure that people with heart pacemakers and electronic implants do not have access
to the V-273.
Make sure that the danger zone is marked.
NOTICE
Overheating caused by unfavorable nominal current!
The nominal current in the data table (p. 37) only applies when operating at room
temperature. The nominal current needed for operating the actuator must be adjusted when
the ambient temperature rises. Otherwise the actuator could be damaged by overheating.
Calculate the nominal current according to the ambient temperature (p. 28).
NOTICE
V-273 heating up during operation!
The heat produced during operation of the V-273 can affect your application.
Ensure sufficient ventilation at the place of installation.
Make sure that the nominal current and the peak current do
not
exceed (p. 37) the
permissible values.
6
Startup and Operation