phytron
29
MA 1263-A010 EN
No. Meaning
Default
P05
P06
not used
P07
Emergency stop ramp
Input for
I1AM0x: in 4000 Hz/s steps
I4XM01: in 1 Hz/s steps
100 000
P08
f
max
MØP (mechanical zero point)
Run frequency during initializing (referencing)
Enter in Hz (integer value)
I1AM0x: 40 000 maximum
I4XM01: 4 000 000 maximum
4000
P09
Ramp MØP
Ramp during initializing, associated to parameter P08
Input for
I1AM0x: in 4000 Hz/s steps
I4XM01: in 1 Hz/s steps
4000
P10
f
min
MØP Run frequency for leaving the limit switch
range
Enter in Hz
400
P11
MØP offset for limit switch dir (away from
“LIMIT+” switch, towards “LIMIT–” switch)
Distance between reference point MØP and limit switch
activation
Unit: is defined in parameter P02
P11>=0
0
P12
MØP offset for limit switch direction – (away from
“LIMIT–” switch, towards “LIMIT+” switch)
Distance between reference point MØP and limit switch
activation
Unit: is defined in parameter P02
P12>=0
0