ProfiNet / ProfiBus interfaces
MA 1263-A010 EN
28
9 List of Parameters
No. Meaning
Default
P01
Type of movement (free run, relative / absolute,
reference run)
0 = Rotational movement (ignoring limit switches)
1 = Hardware limit switches are monitored
for XY tables or other linear systems,
2 limit switches:
Mechanical zero and limit direction –
Limit dir
2 = Software limit switches are monitored
3 = Hardware and software limit switches are monitored
0
P02
Measuring units of movement: only used for displaying
1 = step
2 = mm
3 = inch
4 = degree
1
P03
Conversion factor for the thread
1 step corresponds to ...
If P03 = 1 (steps) the conversion factor is 1.
Computing the conversion factor:
revolution
per
steps
of
Number
Thread
factor
Conversion
=
Example
01
.
0
400
4
=
=
factor
Conversion
:
4 mm thread pitch
200-step motor = 400 steps/rev. in the half step mode
1
P04
Start/stop frequency
The start/stop frequency is the maximum frequency to
start or stop the motor without ramp. At higher frequen-
cies, step losses or motor stop would be the result of a
start or stop without ramp. The start/stop frequency
depends on various factors: type of motor, load,
mechanical system, power stage.
The frequency is programmed in Hz.
400