30 |
NUC Commands
All valid serial command shown in Table 15 should be sent as:
NUC <Command> <Optional Payload><CR><LF>
Table 15: NUC commands
Command
Optional Payload
Description
?
NUC help menu
gain
on
off
Enables the non-uniformity gain correction
Disables the non-uniformity gain correction
offset
on
off
Enables the non-uniformity offset correction
Disables the non-uniformity offset correction
editbpf
Invokes the bad pixel file editor. Please contact
PHOTONIS for additional information.
global gain
Displays the global gain for the non-uniformity
correction on the console
global gain
xxx
Sets global gain for the non-uniformity correction
to xxx
global offset
Displays the global offset for the non-uniformity
correction on the console
global offset
xxx
Sets global offset for the non-uniformity
correction to xxx
load gain
[filename]
Loads gain file [filename] into bufferset
load offset
[filename]
Loads offset file [filename] into bufferset
status
Displays current status of the non-uniformity
correction on the console
use bufferset
Displays the current buffer set in use
use bufferset
xx
Sets bufferset number to xx to use for gain and
offset tables
Temperature Commands
All valid serial command shown in Table 16 should be sent as:
TEMP <Command> <Optional Payload><CR><LF>
Table 16: Temperature commands
Command
Optional Payload
Description
?
Temperature help menu
rd
[xx]
Reads temperature sensor register xx (0 is
currently the default on the NOCTURN camera)
wr
[xx] [dd]
Writes the temperature register [xx] with value
[dd]
The NOCTURN only has one temperature sensor available. It can be read by sending the following
command:
TEMP RD 0<CR><LF>
NVT 200-LC-4019
©2015 PHOTONIS Digital Imaging LLC
Revision: C.04
All Rights Reserved
Page 30 of 39