CameraLink
®
Frame Grabber Setup
Please refer to the CameraLink® frame grabber manual to setup the configuration to match the
parameters shown in Table 5.
Table 5: CameraLink® Frame Grabber Configuration Details
Parameter
Value
Unit
Pixel Clock per Tap (30/50/60fps Mode)
48
MHz
Pixel Clock per Tap (100fps Mode)
72
MHz
Number of Taps
2 Interlaced Vertically
NA
Grayscale Resolution
10
Bits
Data Width pre Valid
8
Pixels
Data Height pre Valid
1
Line
Data Width Valid
1280
Pixels
Data Height Valid
1024
Pixels
Data Width post Valid
0
Pixels
Data Height post Valid
0
Pixels