6. Product information
6.1 Mode of operation
The electric cylinder is to be used exclusively for the adjustment of guided components or other
adjustment tasks of a similar nature. The drive is carried out using the integrated DC motor.
6.2 Versions
The Lambda electric cylinder is available in three versions.
6.3 Variants
The following versions are available for the Lambda electric cylinder:
•
•
•
Without anti-trap protection: pull and press at full force.
With anti-trap protection with tensile: press with full force and pull with very little force. With
anti-trap protection with pressure: pull with full force and press with very little force.
6.3.1 Other variants / options
•
•
•
•
With potentiometer 10 k
.
Signal contact potential-free or non-isolated.
Adjustment without power (mechanical extraction).
Power supply 12 VDC.
37
Version 1
Version 2
Version 3
Compressive force
6000 N
4500 N
2000 N
Tensile force
4000 N
4000 N
2000 N
Lifting speed
5 mm/s
8 mm/s
21 mm/s