6. Product information
6.5 Technical specifications
39
Version 1
Version 2
Version 3
Stroke length
up to 400 mm
up to 600 mm
Dimension A - Installation dimension
Stroke smaller than 400 mm = 175 mm
Stroke greater than or equal to 400 mm = 225 mm
Standard lifting length
100; 150; 200; 250; 300; 400; 500 and 600 mm
Lifting force, pressure
6000 N
4500 N
2000 N
Lifting force, tensile
4000 N
4000 N
2000 N
Lifting speed
5 mm/s
8 mm/s
21 mm/s
Protection class (static)
IP 66
Power input
7 A (15 A)
Voltage (VDC)
24 VDC (12 VDC)
Power consumption
180 W
Ambient temperature
Storage temperature
-10 deg. Celsius to +60 deg. Celsius
-20 deg. Celsius to +60 deg. Celsius
Anti-trap protection to tension /
pressure
available as an option
Activation force for clamping
protection
100 N to 300 N
60 N to 220 N
20 N to 80 N
Adjustment without power
possible in some cases
available as an option
Self-locking
Yes
Stroke tube routing
Sliding bearing
Limit switch of the stroke end
positions
installed permanently
Repeatability
0.5 mm (depending on the control and configuration)
Operating mode
ED 10%; 2 minutes operation / 18 minutes break
Overheat protection
installed
Maintenance
maintenance-free
Colour
Plastic parts black or grey RAL9002
Electric connection
2-pin plug; DIN43650-A
Custom stroke lengths / installation
lengths
on request
Installation position
as desired, without lateral forces