11

Cabling notes

11.1

Connecting the supply voltage

Figure 10

Individual or redundant supply

Operation as a single device

Supply the supply voltage to the module via terminal blocks 

1 (24 V) and 2 (0 V).

Operation in a star coupler topology

If you operate the devices in a star coupler topology, the 

supply voltage must only be supplied to the first device in the 

station. The remaining devices are supplied via the DIN rail 

connector. You can create a redundant supply concept by 

connecting a second power supply unit to another device in 

the topology.

Supply via system power supply

Alternatively, you can supply the star coupler topology using 

the MINI-SYS-PS 100-240AC/24DC/1.5 (Order No. 

2866983) or MINI-PS-100-240AC/24DC/1.5/EX (Order. No. 

2866653) system power supply. It is connected via two DIN 

rail connectors.

Usually the system power supply is mounted as the first de-

vice in a topology. A second power supply unit can be used 

to create a redundant supply concept.

11.2

Connecting the data cables

Connect the RS-232 connection via the D-SUB 9 pin 

strip on the top of the device (see Figure 12).

Figure 11

Wiring the D-SUB pin strip

Figure 12

Connecting the data cables

CAUTION: Electrical voltage

The device is only intended for operation with 

SELV according to IEC 60950/EN 60950/

VDE 0805.

2

4 V

0

 V

2

4 V

0

 V

0

 V

2

4 V

NOTE: Device damage

Use shielded twisted pair data cables. Connect 

the cable shielding at both ends of the transmis-

sion path.

Notes on star structures:

Always connect the master station to the RS-232 

interface of the first PSI-MOS device in the star 

coupler topology. The other RS-232 interfaces 

cannot be used.

Always connect only one RS-232 slave device to 

each FO converter at the end of a star line.

2

3

5

7

4
6
7

2

0

8

6

5

D

-SUB

2

5

9

D

-SUB 

9

3

2

Pe

r

iphe

r

ie

PSI-M

O

S-

R

S2

3

2-...

max.
1

5

 m

Tx

D

R

x

D

GN

D

D

T

R

D

S

R

R

TS

C

TS

4

2

5

4
6
7
8

3

Tx

D

R

x

D

GN

D

D

T

R

D

S

R

R

TS

C

TS

V

CC

T

D

RD

F

O

SIGNAL

E

RR

A

E

RR

B

D

TE

DC

E

V

CC

T

D

RD

F

O

SIGNAL

E

RR

D

TE

DC

E

V

CC

T

D

RD

F

O

SIGNAL

E

RR

A

E

RR

B

D

TE

DC

E

Maste

r

Содержание PSI-MOS-RS232/FO 1300 E

Страница 1: ...within a modular star coupler occurs automatically via the backplane The system supports progressive transmis sion speeds from 4 8 kbps to 115 2 kbps The devices are also equipped with comprehensive...

Страница 2: ...res 10 9 Configuration 11 9 1 Operation in a point to point connection DIP 1 11 9 2 Operation in a star structure DIP 1 11 9 3 Connection to fiber optic interfaces from third party suppliers DIP 2 12...

Страница 3: ...40AC 24DC 1 5 2866983 1 Power supply unit for use in zone 2 potentially explosive areas ATEX MINI PS 100 240AC 24DC 1 5 EX 2866653 1 End bracket CLIPFIX 35 3022218 50 DIN rail connector power supply a...

Страница 4: ...dBm 62 5 125 m multi mode fiberglass 3 4 dBm 50 125 m multi mode fiberglass Receiver sensitivity Minimum single mode fiberglass Minimum multi mode fiberglass Maximum both fibers 26 5 dBm 25 5 dBm 0 d...

Страница 5: ...Ex nA nC IIC T4 Gc X UL 508 listed 508 recognized Conformity with EMC Directive 2014 30 EU Immunity test according to EN 61000 6 21 Electrostatic discharge ESD Air discharge Contact discharge EN 6100...

Страница 6: ...in mm D SUB COMBICON 24V 1 11 3 12 4 Alarm DC DC gn DIN rail connector 24 V 0 V GND Data A Data B Bus management Function TD RD Fiber optic port Broken fiber rd ERR A Fiber optic diagnostics port A y...

Страница 7: ...mits This device is not designed for use in atmospheres with a risk of dust explosions The switches of the device that can be accessed may only be actuated when power to the device is discon nected Th...

Страница 8: ...6 2 Star structures You can network addressable RS 232 devices within a star structure as a master slave network Depending on the number of star lines required several terminal devices are connected t...

Страница 9: ...ED 9 Slide switch for DTE DCE adaptation 10 FO SIGNAL LED 11 FO SIGNAL LED 12 FO SIGNAL LED 13 ERR LED 14 Fiber optic transmitter 15 Fiber optic receiver Diagnostic and status indicators Des Color Mea...

Страница 10: ...4 Port assignment for point to point connections 8 2 Port assignment for star structures By means of full duplex mode the electrical interface com municates with all connected fiber optic ports of th...

Страница 11: ...s 9 2 Operation in a star structure DIP 1 Devices in the star coupler topology For each device in the star coupler topology set DIP 1 to ON STAR Devices at the end of a star line No further settings a...

Страница 12: ...IP 6 to ON multi mode for operation on a multi mode fiberglass 50 125 m or 62 5 125 m Leave DIP 6 set to OFF single mode for operation on a single mode fiberglass 9 125 m factory setting If you are no...

Страница 13: ...must be hooked onto the top edge of the DIN rail see Figure 9 Make sure that it is aligned correctly with the DIN rail connectors Once the device has been snapped on properly check that it is fixed se...

Страница 14: ...use in zone 2 Devices that are installed in zone 1 must not be connected to the fi ber optic interface Area with a danger of dust explosions The device is not designed for installation in areas with a...

Страница 15: ...t de vice in a topology A second power supply unit can be used to create a redundant supply concept 11 2 Connecting the data cables Connect the RS 232 connection via the D SUB 9 pin strip on the top o...

Страница 16: ...he device is equipped with a floating switching output for error diagnostics terminals 3 11 and 4 12 The switch contact opens on the relevant device in the event of the following Supply voltage failur...

Страница 17: ...tter at device 1 Fiber connection RD receiver at device 2 WARNING Danger of eye injuries During operation do not look directly into the transmitter diodes or use optical aids to look into the fibergla...

Отзывы: