5 / 17

MTBF according to Telcordia standard

Ambient temperature 25 °C

Ambient temperature 40 °C

549 years

113 years

Free from substances that would hinder coating with paint or 

varnish

According to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central 

standard

Vibration resistance

5g according to IEC 60068-2-6, 2.5 h each in XYZ direction, 

criterion A

Shock resistance

15g according to IEC 60068-2-27 with 11 ms pulse length, 

criterion C

Free fall

1 m without packaging according to IEC60950

Air clearances and creepage distances

DIN EN 60664-1/VDE 0110-1, DIN EN 50178, DIN EN 60950

General data [...]

Tests/approvals

CE

CE-compliant

ATEX (Please follow the special installation instructions in 

the documentation.)

 II 3 G Ex nA nC IIC T4 Gc X

UL

508 listed

508 recognized

Conformity with EMC Directive 2014/30/EU

Immunity test according to EN 61000-6-2

1

Electrostatic discharge (ESD)

Air discharge

Contact discharge

EN 61000-4-2

Criterion B

2

8 kV

6 kV

Electromagnetic HF field

Amplitude modulation

EN 61000-4-3

Criterion A

3

10 V/m

Fast transients (burst)

Signal

Power supply

EN 61000-4-4

Criterion B

2

2 kV/5 kHz

2 kV/5 kHz

Surge current loads (surge)

Signal

Power supply

EN 61000-4-5

Criterion B

2

1 kV/42 

0.5 kV/2 

Conducted disturbance variables

EN 61000-4-6

Criterion A

3

10 V

Noise emission test according to EN 61000-6-4

Noise emission of housing

EN 55011

4

Class A, Industrial application, without special in-

stallation measures

1

EN 61000 corresponds to IEC 61000

2

Criterion B:

 Temporary adverse effects on the operating behavior, which the device corrects automatically

3

Criterion A:

 Normal operating behavior within the specified limits

4

EN 55011 corresponds to CISPR11

Содержание PSI-MOS-RS232/FO 1300 E

Страница 1: ...within a modular star coupler occurs automatically via the backplane The system supports progressive transmis sion speeds from 4 8 kbps to 115 2 kbps The devices are also equipped with comprehensive...

Страница 2: ...res 10 9 Configuration 11 9 1 Operation in a point to point connection DIP 1 11 9 2 Operation in a star structure DIP 1 11 9 3 Connection to fiber optic interfaces from third party suppliers DIP 2 12...

Страница 3: ...40AC 24DC 1 5 2866983 1 Power supply unit for use in zone 2 potentially explosive areas ATEX MINI PS 100 240AC 24DC 1 5 EX 2866653 1 End bracket CLIPFIX 35 3022218 50 DIN rail connector power supply a...

Страница 4: ...dBm 62 5 125 m multi mode fiberglass 3 4 dBm 50 125 m multi mode fiberglass Receiver sensitivity Minimum single mode fiberglass Minimum multi mode fiberglass Maximum both fibers 26 5 dBm 25 5 dBm 0 d...

Страница 5: ...Ex nA nC IIC T4 Gc X UL 508 listed 508 recognized Conformity with EMC Directive 2014 30 EU Immunity test according to EN 61000 6 21 Electrostatic discharge ESD Air discharge Contact discharge EN 6100...

Страница 6: ...in mm D SUB COMBICON 24V 1 11 3 12 4 Alarm DC DC gn DIN rail connector 24 V 0 V GND Data A Data B Bus management Function TD RD Fiber optic port Broken fiber rd ERR A Fiber optic diagnostics port A y...

Страница 7: ...mits This device is not designed for use in atmospheres with a risk of dust explosions The switches of the device that can be accessed may only be actuated when power to the device is discon nected Th...

Страница 8: ...6 2 Star structures You can network addressable RS 232 devices within a star structure as a master slave network Depending on the number of star lines required several terminal devices are connected t...

Страница 9: ...ED 9 Slide switch for DTE DCE adaptation 10 FO SIGNAL LED 11 FO SIGNAL LED 12 FO SIGNAL LED 13 ERR LED 14 Fiber optic transmitter 15 Fiber optic receiver Diagnostic and status indicators Des Color Mea...

Страница 10: ...4 Port assignment for point to point connections 8 2 Port assignment for star structures By means of full duplex mode the electrical interface com municates with all connected fiber optic ports of th...

Страница 11: ...s 9 2 Operation in a star structure DIP 1 Devices in the star coupler topology For each device in the star coupler topology set DIP 1 to ON STAR Devices at the end of a star line No further settings a...

Страница 12: ...IP 6 to ON multi mode for operation on a multi mode fiberglass 50 125 m or 62 5 125 m Leave DIP 6 set to OFF single mode for operation on a single mode fiberglass 9 125 m factory setting If you are no...

Страница 13: ...must be hooked onto the top edge of the DIN rail see Figure 9 Make sure that it is aligned correctly with the DIN rail connectors Once the device has been snapped on properly check that it is fixed se...

Страница 14: ...use in zone 2 Devices that are installed in zone 1 must not be connected to the fi ber optic interface Area with a danger of dust explosions The device is not designed for installation in areas with a...

Страница 15: ...t de vice in a topology A second power supply unit can be used to create a redundant supply concept 11 2 Connecting the data cables Connect the RS 232 connection via the D SUB 9 pin strip on the top o...

Страница 16: ...he device is equipped with a floating switching output for error diagnostics terminals 3 11 and 4 12 The switch contact opens on the relevant device in the event of the following Supply voltage failur...

Страница 17: ...tter at device 1 Fiber connection RD receiver at device 2 WARNING Danger of eye injuries During operation do not look directly into the transmitter diodes or use optical aids to look into the fibergla...

Отзывы: