Service Modes, Error Codes, and Fault Finding
5.
•
MOP_RXS3_x.x.x.x.zip.
Contains the MOP LED dimming
software and is upgradeable via USB (UPG). This SW is
not part of the FUS autorun.upg!
Important remark
: there is no fall back LED dimming
software available in case mains interruption occurs while
upgrade process is running. The TV set will get stucked
and reboots endlessly; the only way to recover is to use
EJTAG.
•
OAD_Q5492_x.x.x.x.zip.
Not to be used by Service
Technicians.
•
OpenSourceFile_Q5492_x.x.x.x.zip.
Not to be used by
Service technicians.
•
PQPrivate_Q5492_x.x.x.x.zip.
Not to be used by Service
technicians.
•
StandbySW_CFTxx_x.x.x.x_commercial.zip.
Contains
the Stand-by software in “upg” and “hex” format.
–
The “StandbySW_xxxxx_prod.upg” file can be used to
upgrade the Stand-by software via USB.
–
The “StandbySW_xxxxx.hex” file can be used to
upgrade the Stand-by software via ComPair.
–
The files “StandbySW_xxxxx_exhex.hex” and
“StandbySW_xxxxx_dev.upg” may not be used by
Service technicians (only for development purposes).
•
UpgradeAll_Q5492_x.x.x.x_commercial.zip.
Only for
production purposes, not to be used by Service
technicians.
Caution: Never try to use this file, because it will
overwrite the HDCP keys ! ! !
•
UpgradeExe_Q5492X_x.x.x.x.zip.
Not to be used by
Service Technicians.
•
Ambilight_Q5492_x.x.x.x.zip.
Not to be used by Service
technicians.
•
Cabinet_Q5492_x.x.x.x.zip
. Not to be used by Service
technicians.
•
Display_Q5492_x.x.x.x.zip
. Not to be used by Service
technicians.
•
LightGuide_TV522_x.x.x.x_.zip.
Not to be used by
Service Technicians.
•
LedProfile_LEDPRF_x.x.x.x_.zip.
Not to be used by
Service Technicians.
•
ProcessNVM_Q5492_x.x.x.x.zip.
Default NVM content.
Must be programmed via ComPair or can be loaded via
USB, be aware that all alignments stored in NVM are
overwritten here.
5.9.5
Content of the MOP Ambilight ARM SW File
•
MOP_AMBILIGHT_V1-X_UPG_jettsigned.zip. Contains
the MOP ambientlight software (ARM processor on the
DC-DC AL interface board) and is upgradeable via USB
(UPG). This SW is not part of the FUS autorun.upg! and is
not available in the One-Zip software file but provided
separately via the commercial Philips website (software for
servicers only).The way of work on how to upgrade is
included in the zip file.
Important remark
: the upgrade process of the ARM
processor is not completely done when the message
“Operation Successful” is shown on the display. To be sure
the upgrade has totally been finished, wait until the
ambilight flashes the colour “green” a few times.
5.9.6
UART logging 2K9 (see section “