PHI 2000 PURO/VAPORE 07 DISASSEMBLY
1/8
7.1. Outer shell
A
A
A
Remove the dreg drawer, water tank, mush
-
room finger protection device on the coffee
container lid and coffee container, then loosen
the screws shown.
The USA type is inserted a grid Protective hand
to replace the mushroom finger protection
Remove the dreg drawer, water tank, mushroom
finger protection device on the coffee container
lid, then loosen the screws shown.
Slide out the steam hose protection, lift the cover at the rear by pressing down gently on the cooling
vents to help detach the anchoring tabs, then pull it away from the steam hose, taking care not to
scratch it. (Only for Vapore)
Disassembling the Top cover
Disassembling the side cover
Loosen the screws shown and slide out the side cover; be careful of the protrusions
(A)
on the base.