2. Z-Wave’s Configuration

Configuration

Parameter

Function

Size

(Byte)

Value

Unit

Default

Description

1

Watt Meter

Report  

Period

2

0x01-

0x7FFF

5s

720

720*5s=3600s=1

hour

2

KWH 

Meter 

Report  

Period

2

0x01-

0x7FFF

10min

6

6*10min= 1 hour

3

Selected 

Relay

1

1-3

3

1

Relay1 

2

Relay2

3

Relay1 & 

Relay2

4

Edge or 

Pulse 

mode or 

Edge-

Toggle 

mode

1

1-3

1

1

Edge mode

2

Pulse mode

3

Edge-Toggle     

mode

5

Threshold 

of current 

for Load 

Caution

2

10-750

0.01A

750

750*0.01A = 7.5A

6

Threshold 

of KWH for

Load 

Caution

2

1-10000

1KWh

10000

7

Restore 

switch 

state mode

1

0-2

1

0 : Switch off

1 : Last switch 

state

2 : Switch on

8

Auto off 

timer 

2

0-0x7FFF

1s

0

0 : Disable auto off 

function

1-0x7FFF : 1s ~

32767s

9

RF off

command 

mode

1

0-3

0

0 : Switch off

1 : Ignore

2 : Switch toggle

3 : Switch on

10

Existence 

of 

Endpoint3

1

1-2

1

1 : Endpoint3 exist

2 : No Endpoint3

14

Watt 
differential 
report 
mode

1

0-4

1

0 : Disable

1 : 5%

2 : 10%

3 : 15%

4 : 20%

31

Select Auto
Report 

1

1-2

1

1 : Basic type

2   :   MultiChannel

15

Содержание PAN04

Страница 1: ... of light like incandescent fluorescent and LED light This in wall switch module is able to detect Instant power wattage and overload current 7 5A with resistive load of connected light or appliances When detect ing overload state the Module will be disabled and its On Off button will be lock out of which LED will flash quickly However disconnect and re connect the Module will reset its overload c...

Страница 2: ...ler does not allocate a node ID to the Switch LED 2 second on 2 second off Inclusion 1 Put your Z Wave controller into inclusion mode by following the instructions provided by the controller manufacturer One press one flash LED 2 Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion mode Exclusion 1 Put your Z Wave controller into exclusion mode by following the instructions pr...

Страница 3: ...t mode the switch is in view from the LED for identification State Type LED Indication Normal Whatever we switch On and off of the PAN04 by S1 S2 or On Off button or RF command the LED will lights up 1 second and then off No node ID Under normal operation when the Switch has not been allocated a node ID the LED flashes on and off alternately at 2 second intervals By pressing S1 S2 or On Off button...

Страница 4: ...ugged into the Switch will turn OFF Programming 1 Basic Command Class Binary Switch Command Class The Switch will respond to BASIC and BINARY SWITCH commands that are part of the Z Wave system 1 1 BASIC_GET BINARY_SWITCH_GET Since the switch have two relay the Switch will report its On Off state to the Controller by setting Configuration parameter 3 Configuration parameter 3 1 Report ON when relay...

Страница 5: ...elay 2 Command Class Basic Basic Set Value 1 99 255 0xFF the load attached to the Switch turns on Command Class Basic Basic Set Value 0 0x00 the load attached to the Switch turns off Command Class Switch Binary Switch Binary Set Value 1 99 255 0xFF the load attached to the Switch turns on Command Class Switch Binary Switch Binary Set Value 0 0x00 the load attached to the Switch turns off 1 Z Wave ...

Страница 6: ... 0x01 Meter Type 0x01 Precision 1 Scale 0x02 Size 4 Meter Value W 2 1 3 overload alarm report command When PAN04 detect the overload it will send Alarm Report to the correspond Group The content of Alarm Report Alarm report command Command_Class_Alarm Alarm_Report Alarm Type 0x08 Alarm Level 0xFF 2 2 Response to Meter Get Command The Switch will report its 1 instant Power Consumption Watt or 2 acc...

Страница 7: ... 1 0x00 KWh Meter Value 2 0x01 KWh Meter Value 3 0x38 KWh Meter Value 4 0xA3 KWh Accumulated power consumption KW h Meter Value 2 65536 Meter Value 3 256 Meter Value 4 800 35 KW h 2 2 3 Clearing accumulated power consumption Whenever re start counting the accumulated power consumption is needed you can use Meter Reset Command to clear it Meter Reset Command Command Class Meter Meter Reset 2 2 4 AC...

Страница 8: ... Command Command Class Meter Meter Get Scale 0x06 PF Meter Report Command Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF It means that the load power factor is 0 99 2 3 Multi Channel Command Class Version 3 PAN04 also support Muti Channel command class ver...

Страница 9: ... ON report OFF 0x00 when both Relay 1 and Relay2 are OFF Bit Address Destination End Point 0x05 Bit Address 0 Destination End Point Command Class 0x25 Command_Class_Switch_Binary 0x25 Command 0x03 Switch_Binary_Report 0x3 Parameter 1 0xFF ON 0xFF OFF 0x00 2 3 2 BINARY_SWITCH_SET By using BINARY_SWITCH_SET Command of Multi Channel Command Class Encapsulation Command you can switch Relay1 ON OFF by ...

Страница 10: ...x03 Bit Address 0 Destination End Point range1 3 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x03 Meter_Supported_Get 0x03 Below is the example show PAN04 report to last command COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Bit Address Destination End Point 0x01 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x04 Meter_Supported_Report 0x04 Parameter ...

Страница 11: ...l this value will be 0 Bit Address Destination End Point 0x03 Bit Address 0 Destination End Point range1 3 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x01 Meter_Get 0x01 Parameter 1 0x00 Scale KWH 0x00 Accumulated power consumption KWH Report example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Meter report Endpoint3 Bit Address Destination End Point 0x05 B...

Страница 12: ...oint 0x03 Meter report Endpoint3 Bit Address Destination End Point 0x05 Bit Address 0 Destination End Point command inquirer s Endpoint value Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x02 Meter_Report 0x02 Parameter 1 0x21 Scale Bit2 0 Rate Type 0x01 Meter Type 0x01 Parameter 2 0x34 Precision 1 Scale Bit1Bit0 0x02 Size 4 Parameter 3 0x00 Instant Power Consumption 0x000003EA 100 2W Pa...

Страница 13: ...Parameter 2 0x22 Precision 1 Scale Bit1Bit0 0x00 Size 2 Parameter 3 0x09 Voltage 0x0910 232 0V Parameter 4 0x10 2 3 5 4 Get load current I from endpoint Meter_GET example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x05 this is the endpoint of command inquirer here we assume endpoint is 5 if the inquirer doesn t support multi Channel this value will be 0 Bit Address Destin...

Страница 14: ...e endpoint is 5 if the inquirer doesn t support multi Channel this value will be 0 Bit Address Destination End Point 0x03 Bit Address 0 Destination End Point range1 3 Command Class 0x32 Command_Class_Meter_V3 0x32 Command 0x01 Meter_Get 0x01 Parameter 1 0x30 Scale PF 0x06 PAN04 power factor report example COMMAND_CLASS_MULTI_CHANNEL MULTI_CHANNEL_CMD_ENCAP Source End Point 0x03 Meter report Endpoi...

Страница 15: ...e mode 5 Threshold of current for Load Caution 2 10 750 0 01A 750 750 0 01A 7 5A 6 Threshold of KWH for Load Caution 2 1 10000 1KWh 10000 7 Restore switch state mode 1 0 2 1 0 Switch off 1 Last switch state 2 Switch on 8 Auto off timer 2 0 0x7FFF 1s 0 0 Disable auto off function 1 0x7FFF 1s 32767s 9 RF off command mode 1 0 3 0 0 Switch off 1 Ignore 2 Switch toggle 3 Switch on 10 Existence of Endpo...

Страница 16: ... Class or Meter Command Class V3 3 3 1 Selected Relay1 Only relay1 can be controlled and report 3 3 2 Selected Relay 2 Only relay2 can be controlled and report 3 3 3 Selected Relay1 and Relay2 Default select is 3 Both relay1 and relay2 can be controlled and report Set command Relay state Basic_Set or Binary_Switch_Set ON Both Relay1 and Relay2 ON Basic_Set or Binary_Switch_Set OFF Both Relay1 and ...

Страница 17: ...nd to the node of correspond Group minimum value is 1KWh and default value is 10000 kWh 3 7 Restore switch state mode Whenever the AC power return from lost PAN04 will restore the switch state which could be SWITCH OFF LAST SWITCH STATE SWITCH ON The default setting is LAST SWITCH STATE 3 8 Auto off timer Whenever PAN04 switches to on the auto off timer begin to count down After the timer decrease...

Страница 18: ... setting it in No RF Control state After being set to Protection by sequence state any intentional pressing of On Off button or S2 S2 should be hold longer than 1 second or the switch state will not change However the operation of learn function does not change because learning will not be protected 5 Firmware update over the air OTA PAN04 is based on 500 series SoC and supports Firmware Update Co...

Страница 19: ... 100 240VAC 50Hz 60Hz Maximum Load 6 5A x 2 Channel 230Vac 120Vac Resistive load Range Minimum 40 m in door 100m outdoor line of sight Operating Temperature 0 C 40 C Frequency Range PAN04 1 868 40MHz 869 85MHz EU PAN04 2 908 40MHz 916 00MHz USA Canada PAN04 3 922 5MHz 923 9MHz 926 3MHz Japan RF Maximum Power peak 5dBm peak RF Maximum Power Average 10dBm Average RF Modulation Type FSK Frequency Shi...

Страница 20: ...al installation This equipment generates uses and can radiate radio frequency energy and if not in stalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installa tion If this equipment does cause harmful interference to radio or television reception which can be dete...

Отзывы: