2. Z-Wave’s Configuration
Configuration
Parameter
Function
Size
(Byte)
Value
Unit
Default
Description
1
Watt Meter
Report
Period
2
0x01-
0x7FFF
5s
720
720*5s=3600s=1
hour
2
KWH
Meter
Report
Period
2
0x01-
0x7FFF
10min
6
6*10min= 1 hour
3
Selected
Relay
1
1-3
3
1
:
Relay1
2
:
Relay2
3
:
Relay1 &
Relay2
4
Edge or
Pulse
mode or
Edge-
Toggle
mode
1
1-3
1
1
:
Edge mode
2
:
Pulse mode
3
:
Edge-Toggle
mode
5
Threshold
of current
for Load
Caution
2
10-750
0.01A
750
750*0.01A = 7.5A
6
Threshold
of KWH for
Load
Caution
2
1-10000
1KWh
10000
7
Restore
switch
state mode
1
0-2
1
0 : Switch off
1 : Last switch
state
2 : Switch on
8
Auto off
timer
2
0-0x7FFF
1s
0
0 : Disable auto off
function
1-0x7FFF : 1s ~
32767s
9
RF off
command
mode
1
0-3
0
0 : Switch off
1 : Ignore
2 : Switch toggle
3 : Switch on
10
Existence
of
Endpoint3
1
1-2
1
1 : Endpoint3 exist
2 : No Endpoint3
14
Watt
differential
report
mode
1
0-4
1
0 : Disable
1 : 5%
2 : 10%
3 : 15%
4 : 20%
31
Select Auto
Report
1
1-2
1
1 : Basic type
2 : MultiChannel
15