Troubleshooting
Symptom
Cause of Failure
Recommendation
The Switch not working and
LED off
1. The Switch is not
connect to the Main
power
2. The Switch break
down
1. Check power connections
2. Don’t open up the Switch and send it
for repair.
The Switch LED
illuminating, but cannot
control the ON/OFF
Switch of the load attached
Check if the load connect
into the Switch has its
own ON/OFF switch
Set the ON/OFF switch of the load
attached to ON
The Switch LED
illuminating, but the
Detector cannot control
the Switch
1. Not carry out
association
2. Same frequency
interference
1. Carry out association
2. Wait for a while to re-try
LED keep flashing, but
cannot control
Overload occurs
Remove the load attached or check
max. load cannot exceed 7.5A(Resis-
tive load)
Specification
Operating Voltage
100 ~240VAC /50Hz/60Hz
Maximum Load
6.5A
x 2 Channel
(230Vac/120Vac) (Resistive load)
Range
Minimum 40 m in door 100m outdoor line of sight
Operating Temperature
0°C ~ 40°C
Frequency Range
PAN04-1: 868.40MHz; 869.85MHz(EU)
PAN04-2: 908.40MHz; 916.00MHz(USA/Canada)
PAN04-3: 922.5MHz/ 923.9MHz/ 926.3MHz (
Japan
)
RF Maximum Power (peak)
+5dBm (peak)
RF Maximum Power (Average)
-10dBm (Average)
RF Modulation Type
FSK (Frequency-Shift Keying)
** Specifications are subject to change and improvement without notice.
FCC ID : RHHPAN04
DANGER
Danger of electrocution!
All works on the device may be performed only by a qualified and licensed
electrician. Observe national regulations.
Any works introducing changes into the configuration must be always performed
with disconnected voltage.
Choosing a Suitable Location
1. Do not locate the Module facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Module is 0°C~40°C.
3. Do not locate the Module where exists combustible substances or any source
19