3-4-1 Edge mode:
this mode is suitable for the bi stable wall switch that has
indicator point on the switch, and the same position correspond to same
state of relay1 and relay2. if the PAN04 relay change the state because of
receiving Z-Wave RF command, it may need two times of change (switch on
to off or switch off to on) to let relay back to the correspond state.
3-4-2 Pulse mode:
this mode is suitable for the toggle type wall switch to swap
the state of Relay1 or Relay2.
3-4-3 Edge-Toggle mode:
this mode is suitable for the normal bi-stable switch,
every time when change the state of the wall switch will also swap the state
of Relay1 or Relay2.
3-5 Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the
setting value is 750, when the load current of Relay1 or Relay2 over this value,
PAN04 will send current meter report to the node of correspond Group, the
Range of the setting value is from 10 to 750, and the default value is 750.
3-6 Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the
setting value is 10000, when the Accumulated Power Consumption of Relay1 or
Relay2 over this value, PAN04 will send KWh Meter Report command to the
node of correspond Group, minimum value is 1KWh and default value is 10000
kWh.
3-7 Restore switch state mode
Whenever the AC power return from lost, PAN04 will restore the switch state
which could be SWITCH OFF
、
LAST SWITCH STATE
、
SWITCH ON. The
default setting is LAST SWITCH STATE.
3-8 Auto off timer
:
Whenever PAN04 switches to on, the auto off timer begin to count down. After
the timer decrease to zero, it will switch off automatically. However if Auto off
timer is set as 0, the auto off function will be disabled. The default setting is 0.
3-9 RF off command mode
Whenever a switch off command, BASIC_SET
、
BINARY_SWITCH_SET
、
SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of com-
mands.
3-9-1 Switch Off
:
It switches to OFF state. The default setting is Switch Off.
3-9-2 Ignore
:
The switch off command will be ignored.
3-9-3 Switch Toggle
:
It switches to the inverse of current state.
3-9-4 Switch On
:
It switches to ON state.
3-10 Existence of Endpoint3
:
Multi-Channel Command is a good way to control relay1 and relay2 of PAN04
individually. The endpoint3 of PAN04 is related to both relay1 and relay2. In
some condition it becomes redundant in Multi-Channel Command Class. When
the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. The de-
fault value is 1.
Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic.
3-11 Watt differential report mode :
3-11-1 Disable : The function of Watt differential report will be disabled.
17