Phihong USA Corporation
•
East Coast Engineering Center
•
630 Johnson Ave. Suite 102, Bohemia, NY 11716
•
Tel: (631) 610-2289
www.Phihong.com
SNMP MIB:
Phihong USA Corp. registered Enterprise ID:
1.3.6.1.4.1.24852
SNMP Version:
SNMP V2
TCP, UDP Port:
161 SNMP
(Simple Network Management Protocol)
1
OID Name
Type
Value
Description
1.3.6.1.4.1.24852.2.2.1.0 poeSystemActionHubReset
INTEGER
ready(0)
reset(1)
Reset the POE
controller
1.3.6.1.4.1.24852.2.2.2.0 poeSystemActionHubRestoreFactoryDefault
INTEGER
ready(0)
restore(1)
Restore Factory
Defaults
1.3.6.1.4.1.24852.2.2.3.0 poeSystemActionHubSaveConfiguration
INTEGER
ready(0)
save(1)
Save the POE
parameters to flash
1.3.6.1.4.1.24852.2.2.4.0 poeSystemAllPortPowerEnable
INTEGER
ready(0)
disable(1)
enable(2)
Setting this object
at a value enable(2)
enables detection
mechanism for all
port.
Setting this object
at a value
disable(1) disables
detection
mechanism for all
port.
1.3.6.1.4.1.24852.2.2.6.0
poeSystemHWVersion
DisplayString
Read-only
System hardware
version for the
Main board
1.3.6.1.4.1.24852.2.2.7.0 poeSystemNumberOfChannel
INTEGER
Read-only
Number
of
ports
available in the
system
1.3.6.1.4.1.24852.2.2.8.0 poeSystemProductPartNumber
INTEGER
Read-only
poe370U-480-8
poe370U-480-16
poe370U-480-24
1.3.6.1.4.1.24852.2.2.10.0 poeSystemFirmwareVersion
DisplayString Read-only
System firmware
version for the
POE
1.3.6.1.4.1.24852.2.2.11.0 poeSystemDescription
DisplayString
(SIZE (0..10))
Read –Write
System
Description, max.
length of 10
characters
1.3.6.1.4.1.24852.2.2.12.0 poeSystemConsumptionPower ***
INTEGER
Read-only
Measured power
usage expressed in
Watts
1.3.6.1.4.1.24852.2.2.13.0 poeSystemControlACPower ***
INTEGER
Read – Write
Sets the value of
available power in
Watts to be
supplied by
primary(AC)
power source.
or
www.Midspans.com
49