24
Step 5: Fix the Grounding Shield
Use a 60mm heat-shrink tube to fix the grounding shield and leave 40mm shield outside.
Step 6: Make the Phase Wires
Choose 3 wires of the cable as phase wires: U, V, W. Crimping pre-insulated Terminals on the
wires will enhance the connection stability and simplicity between the cable and drive. AxN Size4
series drives are recommended to use the E Series Cord End Terminals manufactured by KST.
Refer to the following table to select the appropriate terminal:
AxN Size4
Cord End Terminals
F (mm)
W (mm)
B (mm)
D (mm)
d1 (mm)
AxN 70.140.4
E16-12
12
8.7
10.0
6.2
5.8
Strip the wires for L mm (
F ≤ L ≤ F+B
), the recommend strip length is F+2 mm, refer to the
following table to select an appropriate length:
AxN Size4
Strip Length (mm)
Recommended Strip Length (mm)
AxN 70.140.4
12 ~ 22.0
14
Step 7: Connect the PE wire with Shield
Use the same method to make the remaining wire as the PE wire. Then crimp the PE wire into the
E16-12 Code End Terminal along with the drainage line.