22
Step 4: Tight the Terminals
Use a 3mm hexagonal torque wrench to tight the hexagonal screws on DC+ and Brk- Terminals .The
nominal torque to tight these terminals is 4.0 ~ 4.5Nm. If the tight torque reaches higher than
8.5Nm, the terminal will be broken.
Step 5
:
Wire Fixing
Use a cable tie to fix the wires on the cable support of AxN Size4 drive.
Step 6: Resistance Measurement
Use an avometer to measure the resistance between DC+ and Brk-. Compare it with the resistance
of the external resistor, if they are the same, then the external resistor has been correctly installed.
WARNING: DO NOT BYPASS THIS STEP! This step can prevent malfunctions like wires shortcut,
brake resistor fault and so on.
Содержание AxN 70.140.4
Страница 2: ......
Страница 7: ...5 1 3 Overall Dimensions...
Страница 15: ...13...
Страница 27: ...25 Step 8 Check and Mark Check every wire and the connection between shield and PE wire then label each wire...
Страница 34: ...32 When the drive is ready N O connects Com and N C disconnects Com illustrated as below...
Страница 47: ...45 Connection diagram Note Only the first and the last CAN node device should use a 120 terminal resistor...