9
Step 4: Make the Grounding Shield
Leave 65mm Shield as the grounding shield and turn it to the outside of the coat. Then, weld a wire
on the shield as the drainage line.
Step 5: Fix the Grounding Shield
Use a 60mm heat-shrink tube to fix the grounding shield and leave 40mm shield outside.
Step 6: Make the Phase Wires
Choose 3 wires of the cable as the phase wires (R, S and T). Crimping pre-insulated Terminals on
the wires will enhance the connection stability and simplicity between the cable and drive. AxN
Size4 series drives are recommended to use the E Series Cord End Terminals manufactured by
KST. Refer to the following table to select the appropriate terminal:
AxN Size4
Cord End Terminals
F (mm)
W (mm)
B (mm)
D (mm)
d1 (mm)
AxN 70.140.4
E16-12
12
8.7
10.0
6.2
5.8
Strip the wires for L mm (
F ≤ L ≤ F+B
), the recommend strip length is F+2 mm, refer to the
following table to select an appropriate length:
AxN Size4
Strip Length (mm)
Recommended Strip Length (mm)
AxN 70.140.4
12 ~ 22.0
14