19
Connection "DeviceNet"
Register
Discrete Input Point
Discrete Output Point
Path
Name
Data type
Service
Comment
7.0.1
Revision
UINT
get
7.0.2
Max Instance
UINT
get
7.0.3
Number of Instances
UINT
get
Instance 1
7.1.1
Bad Flag
BOOL
get
0
7.1.2
Direction BOOL
get
1
7.1.3
Size
UINT
get
16
7.1.4
Data
ARRAY of
get, set
BITS
– 0: No venting
– 1: Direct venting
– 2: Delayed venting
BITS
0
7.1.100
Venting Frequency
USINT
get, set
40-98 %
7.3.101
Venting Time
UINT
get, set
6-3600 s
Path
Name
Data type
Service
Comment
8.0.1
Revision
UINT
get
8.0.2
Max Instance
UINT
get
8.0.3
Number of Instances
UINT
get
Instance 1
8.1.3
Value
BOOL
get
– 0: Pump off
– 1: Pump on and f > 0
8.1.7
Off-On Cycles
UDINT
get
Path
Name
Data type
Service
Comment
9.0.1
Revision
UINT
get
9.0.2
Max Instance
UINT
get
9.0.3
Number of Instances
UINT
get
Instance 1: Pump On/Off
9.1.3
Value
BOOL
get, set
– 0: Pumping station off
– 1: Pumping station on
9.1.5
Fault Action
BOOL
get, set
– 0: Pumping station off
– 1: Hold last state
9.1.6
Fault Action
BOOL
get, set
0
9.1.7
Idle Action
BOOL
get, set
– 0: Pumping station off
– 1: Hold last state
9.1.8
Idle Action
BOOL
get, set
0
Instance 2: TMS/Heating
9.2.3
Value
BOOL
get, set
– 0: TMS/Heating off
– 1: TMS/Heating released
9.2.5
Fault Action
BOOL
get, set
– 0: TMS/Heating off
– 1: Hold last state
9.2.6
Fault Action
BOOL
get, set
0
9.2.7
Idle Action
BOOL
get, set
– 0: TMS/Heating off
– 1: Hold last state
9.2.8
Idle Action
BOOL
get, set
0
Instance 3: Sealing gas
9.3.3
Value
BOOL
get, set
– 0: Sealing gas off
– 1: Sealing gas on
9.3.5
Fault Action
BOOL
get, set
– 0: Sealing gas off
– 1: Hold last state
9.3.6
Fault Action
BOOL
get, set
0
9.3.7
Idle Action
BOOL
get, set
– 0: Sealing gas off
– 1: Hold last state
9.3.8
Idle Action
BOOL
get, set
0