– Tightening torque:
22 ± 2 Nm
7. Then check the torque, since flowing of the sealing material may make it necessary to re-tighten
the screws.
Fig. 11:
Flange connection CF-F, stud screw and through hole
Connection of the stud screw and through hole
1. For the connection of the turbopump, use only the approved mounting kits from Pfeiffer Vacuum.
2. If used: Insert the protective screen or splinter shield with clamping lugs downwards in the turbo-
pump high vacuum flange.
3. Place the seal exactly in the hollow.
4. Connect the flange with the components of the mounting kit according to the figure.
5. Tighten the screw couplings all the way around.
– Tightening torque:
22 ± 2 Nm
6. Then check the torque, since flowing of the sealing material may make it necessary to re-tighten
the screws.
5.5 Connecting the exhaust side
WARNING
Danger of death from poisoning due to toxic gases being expelled without an exhaust line
Exhaust gases and vapors are released from the turbo pumping station unhindered during normal us-
age. In the case of processes with toxic media, there is a risk of injury and danger of death due to
poisoning.
► Note the corresponding regulations for handling toxic substances.
► Toxic process gases should be safely conveyed away via an exhaust line.
CAUTION
Risk of injury from bursting due to high pressure in the exhaust line
Faulty or insufficient exhaust lines cause hazardous situations, e.g. increase in exhaust pressure.
There is a risk of bursting. It is not possible to rule out the risk of injuries due to broken pieces flying
around, high escaping pressure and damage to the equipment.
► Lay the exhaust line without shut-off units.
► Observe the permissible pressures and pressure differentials of the product.
► Check the exhaust line regularly for correct function.
1
2 (G1/8”)
Fig. 12:
Example backing pump exhaust connection
1
Diaphragm pump
2
Exhaust silencer (included in the delivery)
Installation