Adjustment
90
Fig. 13 - 11
5
6
4
3
2
1
13
.10
Changing the temperature sensor
(only on the PFAFF 8320-020)
)
Wait until the heating element has cooled down! Danger of burns!
Disconnect the mains plug!
Danger from electric voltage!
●
Disconnect plug connections
1
and
2
and loosen screw
3
.
●
Remove nut
4
together with the temperature sensor
5
.
●
Attach the new temperature sensor
5
together with new nut
4
.
●
Slide temperature sensor
5
as far into the hot air tube as possible and fi x it in this positi-
on by tightening nut
6
.
●
The rest of the installation takes place in the reverse order.
●
Carry out adjustments as described in
Chapter 13.07.02 Adjusting the height and feed
roller clearance of the hot air nozzle.
Requirement
The temperature sensor
5
should be inserted as far as possible into the hot air tube.