48
Heat sealing
10
.03.07
Example of how to enter a sealing program
The following example should be fi led under program number "
10
" with the comment "ex-
ample
1
", and consists of three seam zones:
1
. Seam zone
1
with switch to another zone after
200
mm seam length
-
2
. Seam zone with reduced welding speed and speed difference between the upper and
lower transport roller and with zone forwarding after
100
mm
-
3
. Seam zone back to original welding speed without speed difference between trans-
port rollers and with zone forwarding after
400
mm
●
Switch on the machine.
●
Call up the programming function..
●
Enter program number "
10
".
●
Confi rm input.
The sealing parameters from the manual sewing mode are taken over for seam zone
1
.
Содержание 8320-010
Страница 105: ...105 95 211 948 95 Part 1 Version 01 04 12 Circuit diagrams 14 02 Circuit diagrams 95 211 948 95...
Страница 106: ...106 Circuit diagrams Version 01 04 12 95 211 948 95 Part 2...
Страница 107: ...107 95 211 948 95 Part 3 Version 01 04 12 Circuit diagrams...
Страница 108: ...108 Circuit diagrams Version 01 04 12 95 211 948 95 Part 4...