Controls
7 - 4
7
.08
Selection switch for operational modes
●
The operational modes of the machine
can be set with the selection switch
1
by
means of four switch settings. The
functions are triggered by two switch
positions on the pedal.
1 = hot sealing
Position 1 - top feed roller is lowered
Position 2 - hot-air nozzle swings into
position, feed rollers run forwards
2 = Test run 1
Position 1 - top feed roller is lowered
Position 2 - hot-air nozzle swings into
position
3 = Test run 2
Position 1 - top feed roller is lowered
Position 2 - feed rollers run forwards
4 = Reverse
Position 1 - no function
Position 2 - feed rollers run backwards
Fig. 7 - 08
1
7
.07
Tape feed regulator/hot-sealing speed
●
The feed of the sealing band is set with
regulator
1
.
●
The hot-sealing speed is set with
regulator
2
.
Fig. 7 - 07
2
1