
14
6
Switching on the machine
.1
Open compressed air on main feed tube.
.2
Open valve 1 (fig. 1).
.3
Check working pressure: 6 bar (pressure gauge 2).
.4
If necessary, carry out an additional regulation of the air pressure (regulating button 3.).
.5
Turn main switch 4 (fig. 2) to “1”:
- Key
lights up
(Emergency-stop button 5, fig 4 must be unlocked.)
.6
Press key
:
- Guide carriage is positioning in basic position.
- Keys
and
light up.
- Machine is operational for “manual operation”.
Note:
For “automatic working procedure” also press key
.
- Keys
and
light up.
.7
Press key
:
- Key
lights up
- Key
goes out.
- Machine is operational.
7
Switching off the machine
Set main switch 4 (fig. 3) at “0” and close valve 1 (fig. 1).
If for some reason the machine is to be switched off immediately,
press EMERGENCY-STOP button 5 (fig. 4).
Содержание 3568-12/12
Страница 1: ...3568 2 12 12 12 Instruction manual 296 12 17 360 Betriebsanleitung engl 01 94...
Страница 6: ...6...
Страница 10: ...10...
Страница 13: ...13 4 1 1 2 3 4 5 3 2 6 ABB_04_01 TIF ABB_16 TIF Wart cdr...
Страница 15: ...15 1 3 2 1 Wart cdr 1 ABB_10 TIF 4 Pult01_68 EPS 5 2 4 3 4 HS_off cdr HS_on cdr CLOSED OPEN...
Страница 21: ...21 1 2 3 3 4 5 6 7 ABB_02_02 TIF 2 1 ABB_06_01 TIF ABB_05 TIF...
Страница 23: ...23 4 3 2 1 3 ABB_02_02 TIF ABB_04 TIF 2 1 SPUL_12 TIF...
Страница 25: ...25 3 1 2 1 2 ABB_04 TIF ABB_06_01 TIF...
Страница 45: ...45 1 1 einlege cdr...
Страница 49: ...49 5 7 7 8 Max Water level 6 Wart cdr...
Страница 51: ...51 12 13 10 12 filter cdr ABB_02_02 TIF 11 9 ABB_26_03 TIF 8 9...