After a repair has been completed, the following test should be performed. These are minimum
recommendations. Depending on what the original error source was, further tests may be necessary.
4.1 Basic inspection
Check that all contacts are properly connected.
• Check all cables and contacts to ensure there is no visible damage.
• Check that the rubber gaiter around the base of the joystick is not damaged. Inspect the gaiter
visually. It should not be subjected to manual handling.
• Ensure that all components of the control system are securely installed.
• Do not over-tighten the mounting screws.
m
WaRnIng
The tests described are minimum recommendations. It is the responsibility of the repair engineer(s) to perform other tests on
the basis of the original error source and the wheelchair model. The necessary information on other tests is available in the
wheelchair service manual. Permobil cannot be held responsible for losses of any kind that may arise when these tests are
conducted, or that arise as a consequence of further relevant tests not being conducted.
m
WaRnIng
These tests should be conducted in an open space, and some kind of clamping device, such as a safety belt, should always be
used. Permobil cannot be held responsible for losses for any kind arising due to these recommendations not being observed.
Содержание C300
Страница 1: ...SERVICE MANUAL Permobil K C300 Power wheelchair US ...
Страница 2: ......
Страница 62: ...62 Cabling overview A B C D E F 1 2 3 4 ...
Страница 63: ...63 Cabling overview Cabling overview R net A B C D E F 5 6 7 8 ...
Страница 64: ...64 Cabling overview A B C D E F 1 2 3 4 ...
Страница 65: ...65 Cabling overview Cabling overview VR2 A B C D E F 5 6 7 8 ...
Страница 67: ......
Страница 68: ...Order no 205221 US 0 ...