38
Output stage
The output stage is fitted with two screws.
Output stage cable connections (Rnet PM80).
R-net Controler
Removal
1.
Switch off the main power switch on the control panel.
2.
Remove the chassis covers. See page 8.
3.
Disconnect the electrical connections from the output stage. Note their positions (see illustration
below).
4.
Remove the output stage by unscrewing its
two mounting screws. See fig.
Fitting
Assemble in reverse order. Older models of C300
have output stages of type PM80, while later
models have output stages of type PM90. When
renewing output stages on older models, PM80
may be replaced by PM90.
Note the location of the cable connections, see
photo above.
Battery
Inhibit
External
charging socket
Output stage cable connections (Rnet PM90).
Motor 1
Left
Motor 2
Right
Battery
Inhibit
External
charging socket
BUS
Actuators
Motor 1
Left
Motor 2
Right
PM80
PM90