Perlight Solar IRT Скачать руководство пользователя страница 21

Perlight Solar IRT Integrated Roof Tile Installation Manual

21

www.perlight.com

V.03.2021 C2.6

10. Maintenance

Cleaning

Under most weather conditions, normal rainfall is sufficient to keep the Perlight Solar module 

glass surface clean. If dirt build-up becomes excessive, clean the glass only with a soft cloth 

using mild detergent and water. USE CAUTION WHEN CLEANING THE BACK SURFACE 

OF THE MODULE TO AVOID PENETRATING THE SUBSTRATE MATERIALS. Solar Modules 

that are mounted flat (0° tilt angle) should be cleaned more often, as they will not ‘’self clean’’ 

as effectively as modules mounted at a 15° tilt or greater. Perlight recommend cleaning the 

modules during the early morning or evening, when the panels will be operating at a lower 

temperature and producing little energy. 

•  Do not lean or stand on the modules during cleaning.

•  Do not use high pressure water jets to clean the solar modules.

Annual Checks

Once a year, check the tightness of terminal screws and the general condition of the wiring. 

Also, check to ensure the mounting hardware is tight and secure. Loose connections will 

result in damage to the array. 

Changed Perlight Solar modules must be of the same kind and type. Do not touch live parts 

of cables and connectors. Use appropriate safety equipment when working (insulated tools, 

insulating gloves, etc.). 

Only trained personnel may carry-out repair work to the PV modules and 

system components.

Cover the front surface of the solar module with an opaque or other material 

when working on the modules. Solar modules generate high voltage when 

exposed to sunlight. 

Содержание IRT

Страница 1: ...Perlight Solar IRT Integrated Roof Tile Installation Manual...

Страница 2: ...w perlight com V 03 2021 C2 6 Table of Contents 1 Introduction 3 2 Class Application 3 3 Applicable Modules 3 4 Warning and Notes 4 5 Permit 5 6 Climate Condition 5 7 Module Structure 5 8 Mounting and...

Страница 3: ...d aging The colour of Perlight IRT is mainly black to blend in with the roof appearance Installation of Perlight IRT is very convenient in comparison to other products with the same functionality the...

Страница 4: ...s likely to experience conditions that produce more current and or voltage than reported at standard test conditions Accordingly the value of Isc and Voc marked on this module should be multiplied by...

Страница 5: ...s 6 Climate Conditions Install the Perlight Solar PV modules in the following conditions Ambient temperature 20 C to 40 C Operating temperature 40 C to 85 C Storage temperature 40 C to 40 C Humidity b...

Страница 6: ...outer left and outer right frames of Left Right modules is different from that of the Middle modules Outer left and right frames of Left Right modules connect to the flashing system Note The module Up...

Страница 7: ...each row Mid Clamp Right 2pcs on every module Material EPDM EPDM Stainless Steel Stainless Steel Part No 2 5 2 6 2 7 2 8 Fittings List Illustration Name Bottom Edge Self Tapping Fixing 5 30mm For IRT...

Страница 8: ...1 Flashing Top Mid 3 1 2 Flashing Top Left 3 2 3 Flashing Top Right symmetrical to 3 2 and has the same function 3 3 4 Flashing Side Left 3 4 5 Flashing Side Right symmetrical to 3 4 and has the same...

Страница 9: ...pacing is repeated on every subsequent row using the lower row anchor position in place of Bottom Edge position Install the modules left to right starting with the bottom row Complete the installation...

Страница 10: ...d Always begin IRT installation from the bottom left Complete the row from left to right before beginning installation of the row above Remember to only use PLM MB 24 L for the leftmost module of each...

Страница 11: ...the centre of Bottom Edge consistent The Upper Frame of the module needs to be fixed with Self Tapping Fixings 5 30mm 2 2 after it is put in place Fit module Mid Clamps Left 2 7 Right 2 8 to first mod...

Страница 12: ...me of this module with the clamp slot of the Bottom Edge Lay the module down and slide down into position Check the placement to make sure the whole frame is in place and the module is placed flat Bec...

Страница 13: ...terproof and drainage function but if the module is locked in the third slot there will be a risk of leakage See below Installation Steps Example Waterproofing and Drainage After the module is in the...

Страница 14: ...on of first row After the installation of the first row of modules is complete Seal Strip 01 2 6 is uniformly placed at the slot of the aluminium Upper Frame of the modules that runs below the anchor...

Страница 15: ...To ensure alignment of the upper and lower joining modules rubber hammer can be used to tap the upper edge of the module Use a wooded strip with equal length to the module against the Upper Frame and...

Страница 16: ...rom the bottom Begin with the bottom row and work upwards Installation of the second row flashing The installation of second row flashing is the same as the first both slide into the module outer Flas...

Страница 17: ...rical in shape and the installation method and function are the same Compared with the Flashing Top 3 1 the left and right virticle extension parts are added which are inserted into the Flashing Side...

Страница 18: ...e tiles at the side of the array Seal Strip 02 may be cut to fit the profile of the tile depending on tile type Finally lay the first row of tiles above the array ensuring the tiles do not protrude ov...

Страница 19: ...Perlight Solar IRT Integrated Roof Tile Installation Manual 19 www perlight com V 03 2021 C2 6 Installation Example...

Страница 20: ...cations where wiring is exposed to the direct rays of the Sun Field connections Connecting cables should be a minimum of 12 AWG copper cables which are UV resistant and insulated for a minimum of 90 C...

Страница 21: ...ng when the panels will be operating at a lower temperature and producing little energy Do not lean or stand on the modules during cleaning Do not use high pressure water jets to clean the solar modul...

Страница 22: ...igned to produce electricity for a minimum of 25 years however the panels may continue to offer useful energy for years to come after this point Once the panels reach the end of their useful life they...

Страница 23: ...Perlight Solar Co Ltd Oufeng Road Muyu Zeguo Town Wenling City Zhejiang Province 317521 China Tel 0086 576 86477920 www perlight com enquiry perlight com...

Отзывы: