Hardware and Connectivity 45
Connecting your IOLAN to the Network
Dedicated Console Port
The rack mount IOLAN models have a dedicated Console port, located on the LED side of the
IOLAN. You can use the supplied Administration cable (with the supplied RJ45
J
DB9F adapter if
needed) to connect a terminal to the Console/Admin port to view diagnostic information and/or
configure the IOLAN using the Menu or Command Line Interface (CLI). You can configure the baud
rate and flow control of the dedicated Console port.
Connecting your IOLAN to the Network
To connect the IOLAN to the network, use a straight-through two-pair Category 5 unshielded
twisted-pair (UTP) cable, or four-pair for Gigabit connections. Connect the RJ-45 Ethernet port on
the IOLAN to a switch, hub, repeater, server or other network device
To connect IOLAN SCS16C-DSFP models, see
Inserting SFP modules into SPF slots
Connecting the IOLAN to the Wi-Fi Network
The following steps allow for each connection to the IOLAN for initial configuration.
Initial Setup - Soft-AP Method
1.
The IOLAN must be powered up.
2.
Press the inset WPS button (using a paper clip) for 4 seconds to enable Soft-AP mode. The
Signal strength LED display should show a pulsing green LED on the third light from the left to
right to confirm you are in Soft-AP mode (See IOLAN Top Views).
3.
The IOLAN is listed on your network connections on your PC or wireless client. It will appear as
SSID: IOLAN-xxxxxx (the last 6 digits of the IOLAN wireless MAC address - found on the
product label).
4.
If using the password entry method:
Select the wireless network on the PC, when a password is requested
enter the password printed on the product label
5.
If using the WPS method:
z
press and release the WPS button on the IOLAN
z
select the wireless network on the PC
z
select the WPS option on the PC’s password dialog box
Note:
To comply with the Telcordia GR-1089 NEBS standard, connect Ethernet interfaces only to
intra-building or unexposed wiring or cabling. The intra-building cable must be shielded and
the shield must be grounded at both ends.
Alternatively, if shielded cabling is not used, the Ethernet wiring (cabling) must directly
connect to equipment within the same frame, cabinet or line-up and the equipment must be
separated by a distance of 6 meters or less.
Note:
WARNING
The intra-building port(s) of the equipment or subassembly is suitable for connection to
intra-building or unexposed wiring or cabling only. The intra-building port(s) of the
equipment or subassembly MUST NOT be metallically connected to interfaces that
connect to the OSP or its wiring. These interfaces are designed for use as intra-building
interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and
require isolation from the exposed OSP cabling. The addition of Primary Protectors is not
sufficient protection in order to connect these interfaces metallically to OSP wiring.