The check engine and emissions malfunction
indicator lamp will illuminate for an inducement-
related fault. There are three inducement categories.
If the inducement is a result of a category 1 fault, then
a level 1 inducement will occur for a duration of 2.5
hours for first occurrence. For repeat occurrence, a
category 1 level 1 inducement fault will occur for a
duration of 5 minutes.
If the inducement is a result of a category 2 fault, then
a level 1 inducement will occur for a duration of 5
hours. There is no repeat occurrence for category 2,
level 1 inducement faults.
If the inducement is a result of a category 3 fault, then
a level 1 inducement will occur for a duration of 18
hours. There is no repeat occurrence for category 3,
level 1 inducement faults.
Illustration 57
g03676218
If a fault condition exists for the entire duration of
inducement level 2, the strategy advances to
inducement level 3. Inducement level 3 has the same
actions for all categories. The check engine lamp and
the emissions malfunction indicator lamp will flash at
a fast rate. A red stop lamp will illuminate solid. The
engine will have a 100% derate and be limited to
1000 rpm or low idle, whichever is greater. If the final
inducement action in ET is set to "Idle Down", then
engine will continue to idle at derated condition. If set
to "Shutdown" , engine will shutdown after 5 minutes.
A key cycle will allow safe harbor mode to initiate.
Safe harbor is only allowed once. After safe harbor,
the engine will be in level 3 final inducement. If set to
"Shutdown", the engine may be restarted, but will
only run for 5 minutes at derated condition before
shutting down again. This action will continue until
the issue is resolved.
Note:
Contact your Perkins dealer for repairs if a fault
occurs.
SEBU9071-06
61
Содержание 2206F-E13TA
Страница 126: ......
Страница 128: ...SEBU9071 2020 Perkins Engines Company Limited All Rights Reserved 128 December 2020 ...