If the inducement is a result of a category 2 fault, then
a level 2 inducement will occur for a duration of 5
hours. For repeat occurrence, a category 2 level 2
inducement fault will occur for a duration of 1 hour.
Illustration 50
g03676141
Reduced Time
If configured to
“
Reduced Time
”
and a fault condition
exists for the entire duration of inducement level 2,
the strategy advances to inducement level 3.
Inducement level 3 has the same actions for all
categories. The check engine lamp and emissions
malfunction indicator lamp will flash at a fast rate. A
red stop lamp will also illuminate solid. The engine
will have a 100% derate and be limited to 1000 rpm
or low idle, whichever is greater. If the final
inducement action in ET is set to
“
Idle Down
”
, then
engine will continue to idle at derated condition. If set
to
“
Shutdown
”
, engine will shutdown after 5 minutes.
A key cycle will allow safe harbor mode to initiate.
Safe harbor is allowed up to three times. After safe
harbor, the engine will be in level 3 final inducement.
If set to
“
Shutdown
”
, the engine may be restarted,
but will only run for 5 minutes at derated condition
before shutting down again. This action will continue
until the issue is resolved.
Note:
Contact your Perkins dealer for repairs if a fault
occurs.
Inducement Strategy for DEF Level
(Worldwide)
Illustration 51
g03676164
If the DEF level falls below 20%, an amber indicator
will illuminate next to the DEF level gauge on the
dash. To avoid inducements, turn the key to the OFF
position and add DEF to the DEF tank.
Illustration 52
g03676169
If the DEF level falls below 13.5%, a level 1
inducement event will occur. The check engine lamp
and the emissions malfunction indicator lamp will
illuminate. The amber indicator next to the DEF level
gauge on the dash will remain lit.
Illustration 53
g03676174
If the DEF level is below 7.5%, a level 2 inducement
event will occur. The check engine lamp and the
emissions malfunction indicator lamp will illuminate
and flash slowly. The amber indicator next to the DEF
level gauge on the dash will remain lit. If the ECM is
configured to
“
Reduced Performance
”
and the DEF
level has reached 1%, the machine will be limited to
75% torque.