17
224
Workshop Manual, TPD 1353E, Issue 3
Peregrine EDi and 1300 Series EDi
Basic diagnostics
Special requirements
1 Try to start the engine and check if the crankshaft rotates.
If it does go to step 3.
If it does not go to step 2.
2 Attempt to rotate the engine crankshaft by hand.
If it does, test the engine starter circuit, see Operation 14-4.
If it does not, inspect the engine for a mechanical obstruction or failure, e.g. a seized engine.
3 Check the fuel system:
Check that there is sufficient fuel in the tank.
If an in-line fuel tap is fitted, switch it to the “ON” position.
Check that there is fuel available at the fuel filter.
Eliminate air from the fuel system, see Operation 11-9.
Check that there is not a leakage of fuel.
Check that the fuel strainer and the filter are clean and serviceable. To renew the strainer and filter, see
Operation 11-1.
Check that the fuel is clean and to the correct specification. Drain some fuel into a clear container and inspect
it for wax or contamination e.g. water, coolant, debris or lubricating oil. Wax can occur in the fuel in extremely
cold conditions. Coolant or lubricating oil in the fuel could be caused by leakage at the seals for the fuel injector
unit.
4 Check the air inlet and the exhaust system:
Check the air filter restriction indicator.
Check that the air filter is clean and serviceable.
Ensure that there is not a blockage in the pipework and that there is no external damage to the pipes or hoses.
5 Check the engine lubricating oil system.
6 Check that the level of engine lubricating oil in the sump is correct.
7 Remove the sensor for engine oil temperature from the rear of the timing case. Check the level of engine
lubricating oil in the reservoir for the high-pressure pump. If the level is too low, the fuel injector units will not
operate.
Check that there is not a leakage of lubricating oil.
Check that the filter for the lubricating oil is clean and serviceable. To renew the canister of the lubricating oil
filter, see Operation 10-1.
Check that the lubricating oil is clean and to the correct specification, drain some lubricating oil into a clear
container and inspect it for contamination e.g. water, fuel, coolant or debris.
Continued
Special tools
Description
Part number
Multimeter
Clear container of approximately 1 litre (1.76 pints) capacity
This document has been printed from SPI². Not for Resale
Содержание 1300 EDi Series
Страница 12: ...xii This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 62: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 76: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 122: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 170: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 190: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 198: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 204: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 226: ...This page is intentionally blank This document has been printed from SPI Not for Resale...