10
Workshop Manual, TPD 1353E, Issue 3
143
Peregrine EDi and 1300 Series EDi
To inspect
Operation 10-14
1 Remove the lubricating oil pump, see Operation 10-12.
2 Clean all the components of the oil pump.
3 Visually inspect the components for damage and wear. If either the inner rotor or the outer rotor are damaged
or worn they must both be renewed as an assembly.
4 Put the outer rotor and the inner rotor into the pump body.
5 Check the outer rotor to body clearance (A). Refer to the relevant Data and dimensions for the "Lubricating
oil pump" on page 17.
6 Check the inner rotor end-float (B). Refer to the relevant Data and dimensions for the "Lubricating oil pump"
on page 17.
7 Fit the lubricating oil pump, see Operation 10-13.
W065
A
W064
B
This document has been printed from SPI². Not for Resale
Содержание 1300 EDi Series
Страница 12: ...xii This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 62: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 76: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 122: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 170: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 190: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 198: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 204: ...This page is intentionally blank This document has been printed from SPI Not for Resale...
Страница 226: ...This page is intentionally blank This document has been printed from SPI Not for Resale...