T
В
-01 Electromechanical box tripod turnstile with two built-in readers
3
Dear Customer,
Thank you for purchasing a box tripod turnstile manufactured by PERCo. Please follow in-
structions given in this Manual carefully, and this high quality product will provide many
years of trouble-free use.
The Assembly and Operation Manual (hereinafter – the Manual) contains the
instructions you will need for safe transportation, storage, installation, operation and
maintenance of the TB-01 electromechanical box tripod turnstile with built-in readers
(hereinafter – the turnstile).
The product installation must be carried out by qualified installers in strict
accordance with the Manual.
Abbreviations adopted in the Manual:
ACS – access control system;
CLB – control logic board;
RC panel – remote control panel.
1. APPLICATION
1.1. The T
В
-01 electromechanical box tripod turnstile with two built-in readers is
designed for pedestrian passage control by proximity cards at entrance points of
industrial facilities, banks, administrative buildings, railway terminals, airports,
etc.
1.2. To ensure fast and convenient passage through the turnstile it is recommended
to install one TB-01 turnstile per each 500 persons working same shift, or based
on the passage pick of 30 persons per minute (Ref. Section 3 for the throughput
rate of the turnstile).
2. OPERATION CONDITIONS
2.1. The TB-01 turnstile with regard to resistance to environmental exposure complies
with GOST 15150 category NF4 (operation in premises with climate control).
2.2. Operation of the TB-01 turnstile is allowed at an ambient air temperature from
+1°
С
to + 40 °
С
and relative air humidity 80% at +25 °
С
.
3. TECHNICAL SPECIFICATIONS
Operating voltage.............................................................................................. 12±1,2VDC
Power consumption ........................................................................................... max. 20 W
Consumption current........................................................................................... max.1,5 A
Throughput rate in a single passage mode. .............................................. 30 persons/min.
Throughput rate in a free passage mode................................................... 60 persons/min.
Passage width.........................................................................................................500 mm
Barrier arm rotation force ................................................................................ max. 3,5 kgf.
Number of readers .............................................................................................................2
Card reading distance at the rated operating voltage:
HID cards ............................................................................................. min. 6 cm
EM-Marin cards.................................................................................... min. 8 cm
RC panel cable length.........................................................................................min. 6,6 m
RC panel overall dimensions (L
х
W
х
H) ................................................... 120
х
80
х
21 mm