 TRANSPORTATION AND STORAGE 

11.1  The turnstile in the original package should be transported in closed freight 

containers or other closed type cargo transport units. 

11.2  During storage and transportation the boxes with the turnstiles can be 

stacked maximum 2 layers high. 

11.3  Storage of the turnstile is allowed in dry indoor facilities at an ambient air 

temperature from -40°

С

 to + 45°

С

 at relative air humidity 80% at 15°

С

.  

11.4  After transportation or storage at temperatures below zero or at high air 

humidity, prior to installation the turnstile must be kept in the original 
package for no less than 24 hours indoors under conditions corresponding 
to operation conditions (Ref. Section 2).  

12. MAINTENANCE 

The turnstile maintenance is required once a year and in case of any technical fail-

ures the turnstile must be serviced immediately after repair works.  The maintenance 
should be carried out by qualified mechanic only after careful study of this Manual.  

 

12.1  To do maintenance proceed as follows: 

  Disconnect the turnstile power supply from the AC mains; 

  Remove the turnstile top cover (3) from the turnstile housing as described in 

Section 6; 

  Lay the cover on a flat steady surface; 

  Inspect the resetting mechanism (a pusher, springs and a roller), optic sensors 

and a damper (Ref. Fig. 10); 

  Remove dust from a rotation sensor disc, located in the spacing of the rotation 

optic sensors, with alcohol-gasoline blend applied with a cloth.  Avoid ingress of 

dust into the operational spacing of the optic sensors;  

  Lubricate with machine oil: 

– four bushes of the resetting mechanism (two – on the rotation axis of 

the pusher, two – on the fastening axis of the springs as well as holes 

in the fastening parts of the springs); 2-3 drops of oil in each lubrication 

point (lubrication points are marked in Figure 10). Avoid ingress of 

lubricant on the rotation sensor disc and the roller surfaces. 

–  lock cylinders of the mechanical release lock (7) and top cover lock (4) 

from a side of the keyhole (4);  

  Check reliability of the cable connections to the CLB connector blocks and if 

necessary tighten the cable fixing screws; 

  Check reliability of the barrier arm (5) fastening, to do so: 

  unscrew the cover (6) screw 

М

4

х

25 with a screw driver and take off 

the cover (6); 

 tighten 

the 

М

8

х

30 bolts of the barrier arms with the S13 socket wrench 

if necessary; 

  put the cover into its operating position and fix it with the screw. 

 

  Check reliability of the turnstile housing fastening to the floor and if necessary, 

tighten the anchor bolts with S17 socket wrench.  

Содержание Turnichetul TB 1

Страница 1: ...TB 1 0 Electromechanical box tripod turnstile with two built in readers Assembly Operation Manual...

Страница 2: ...01 Electromechanical Box Tripod Turnstile with two built in readers Assembly and operation manual...

Страница 3: ...on contingencies and response 14 7 MARKING AND PACKAGING 15 8 SAFETY REQUIREMENTS 15 8 1 Installation safety requirements 15 8 2 Operation safety requirements 16 9 INSTALLATION INSTRUCTIONS 16 9 1 Ins...

Страница 4: ...ce points of industrial facilities banks administrative buildings railway terminals airports etc 1 2 To ensure fast and convenient passage through the turnstile it is recommended to install one TB 01...

Страница 5: ...and operation manual 1 Certificate 1 Package 1 5 OPTIONAL EQUIPMENT SUPPLIED ON REQUEST Wireless remote control kit consists of a receiver and 2 transmitters tags with operation range up to 40m 1 Sir...

Страница 6: ...capture option on entrance or exit the 01 turnstile can be used together with a 01 model featuring a built in card capture reader the TB 01 and TBC 01 models have matching design and dimensions 6 2 D...

Страница 7: ...or of ban on passage 6 2 3 Inside the turnstile housing there is a bracket with a CLB mounted on it with terminal clamps for connection of external devices RC panel ACS outputs wireless remote control...

Страница 8: ...siren and outputs providing the turnstile status data to the ACS controller XT2 connector block Detector to connect an intrusion detector XT3 12VDC connector block to connect the turnstile power suppl...

Страница 9: ...onnection of the devices mentioned in Clause 6 3 1 is made with cables 17 19 20 to the corresponding connector blocks XT1 L and XT1 H of the CLB in accordance with the connection layout Ref Fig A 1 Ap...

Страница 10: ...2 The turnstile is operated by input of a low level signal relatively to the GND contact to Unlock A Unlock B and Stop contacts of the XT1 L connector block As a control element there can be used a n...

Страница 11: ...Det Out and Common and Alarm contacts Alarm 1 and Alarm 2 have normally open contacts The Common contact common contact for the relays at that is not con nected to the negative terminal of the turnsti...

Страница 12: ...rol modes 6 5 1 There are two modes of the turnstile control a pulse control mode and a potential control mode They determine available operating modes of the turnstile Table 3 and Table 4 6 5 2 The c...

Страница 13: ...ection if a low level signal already exists at the set direction input at the moment of passage At the low level signal inputting to the Stop input both directions will lock for the time of the signal...

Страница 14: ...In the pulse control mode control over the turnstile from an ACS controller is similar to that one with the RC panel 6 5 2 In the potential control mode control over the turnstile from an ACS con tro...

Страница 15: ...ow level signal appears at the Fire Alarm input the turnstile turns to the Always locked mode 6 9 3 2 In the potential control mode when a low level signal is removed from the Fire Alarm input both pa...

Страница 16: ...on the internal side of the turnstile top cover and a label inside on the rear side of the turnstile housing To get access to the marking sticker and the label open the top cover 3 To do so proceed a...

Страница 17: ...r similar foundations at least 150mm thick to level the foundation so that the anchoring points of the turnstile lie in the same plane check it with a level to apply reinforcing elements 550 550 200mm...

Страница 18: ...rol cable is 30m The maximum allowed length of the turnstile power cable depends on the cable cross section and should not exceed for cable with 0 75mm2 cross section AWG 18 10 m for cable with 1 5mm2...

Страница 19: ...the CLB Ref Fig 3 and Fig 1 Appendix 9 4 7 Check serviceability and accuracy of all the electrical connections Fix the cables using self adhesive cable tie mounts and nylon cable ties supplied with a...

Страница 20: ...le routing inside the T 01 turnstile housing 1 power cable 2 cable from the RC panel wireless remote control device 3 rotation mechanism connection cable 4 cables of card readers 1 and 2 5 CLB 6 rotat...

Страница 21: ...d connect them to a connector block X1 2 in accordance with color marking for reader 1 blue wire to a clamp 5 yel low wire to a clamp 6 for reader 2 blue wire to a clamp 12 yellow wire to clamp 11 LED...

Страница 22: ...Power supply certificate Do not use substances for cleaning of the turnstile that may cause mechanical dam age or corrosion of the surfaces Do not move through the turnstile passage area any objects...

Страница 23: ...in one direction the countdown of the passage waiting time 5 sec for the opposite direction is resumed Note Pressing the button on the RC panel corresponds to the low level signal supply to the contac...

Страница 24: ...ent table in any sequence The two green indicators left and right are on The two Green arrows left and right are on After passage in the free passage direction the turnstile remains open in both direc...

Страница 25: ...the turnstile remains open in the set direction 3 Both passage directions are open the turnstile is open for passage in both directions The low levels are on the contacts corresponding to the both dir...

Страница 26: ...p the turnstile won t work no light indication on the turnstile housing and the RC panel No supply voltage to the CLB Switch off the turnstile power supply from the AC mains open the turnstile housing...

Страница 27: ...ion 6 Lay the cover on a flat steady surface Inspect the resetting mechanism a pusher springs and a roller optic sensors and a damper Ref Fig 10 Remove dust from a rotation sensor disc located in the...

Страница 28: ...lock locks by pressing the lock cylinder without turning the key Check operation of the T 01 turnstile in accordance with Section 9 of this Manual After maintenance works are complete the turnstile i...

Страница 29: ...T2 Light A 2 3 2 3 button 2 GND 12VDC TPS button 1 yellow blue red common WRC black ACS outputs turnstile control signals on passage A6 1 right button left indicator stop indicator green yellow orange...

Страница 30: ...ector 1 CLIP 4 A3 Emergency unblocking device 1 A4 Remote control panel 1 A5 Siren 1 A6 Access control system 1 A7 Wireless remote control 1 MSRF 4 8 Turnstile power supply unit 1 12 V 1 5 X1 1 Connec...

Страница 31: ...roller NC NO XT5 NC NO R0 D1 X1 2 Light B XT3 12V GND 2 1 XT2 XT1 L XT1 L X1 A3 A2 X1 CM A1 Beeper brown blue R0 D0 12VDC 1 1 orange Det Out Ready PASS B PASS A Common Alarm 2 Alarm 1 12V XT1 H 2 GND...

Страница 32: ...0 00 1 2 Bracket with CLB and connector blocks 1 A3 CLB 1 A4 Cover TBC01 150 00 with a reader 1 1 A5 Cover TBC01 150 00 with a reader 1 2 X1 1 Connector block 1 X1 2 Connector block 1 1 Turnstile cabl...

Страница 33: ...re is a high level at the contacts Stop and Unlock A At this command the passage direction B opens either for 5 sec or until the passage has been effected in this direction or until the command Always...

Страница 34: ...pen for free passage in both directions Active front is at the contact Unlock A while there is a low level at the contacts Unlock B and Stop or active front is at the contact Unlock B while there is a...

Страница 35: ...n open for passage in the direction There is a low level at the contact Unlock while there is a high level at the con tacts Stop and Unlock At this command the direction B opens till the low level sig...

Страница 36: ...PERCo Industrial Tel 7 812 3216172 7 812 3298924 Fax 7 812 2923608 Legal address 123 V ul Leona Pozemskogo Pskov 180600 Russia e mail support perco ru www percoweb com...

Страница 37: ...www percoweb com...

Отзывы:

Похожие инструкции для Turnichetul TB 1