T
В
-01 Electromechanical box tripod turnstile with two built-in readers
13
and counts the time passed since the moment the RC button corre-
sponding to the permitted passage direction
А
(
В
) is ressed.
6.5.2.4 At the barrier arms turning 67° the microcontroller forms signal “PASS
А
(
В
)” (breaking of the contacts “PASS
А
(
В
)” and “Common” oc-
curs).
6.5.2.5 After the barrier arms turning 67° or after 5 seconds since the mo-
ment of pushing the RC button corresponding to the permitted pas-
sage direction
А
(
В
), the microcontroller generates a command to
the control mechanism, which closes the passage direction
А
(
В
)
(drops the upper (lower) edge of the key holt).
6.5.2.6 When the barrier arms reset to home position (barrier arms turning
112°), the microcontroller removes the signal “PASS
А
(
В
)” (contact-
ing of the “PASS
А
(
В
)” and “Common” takes place).
6.5.3 The “Always free” operating mode particularity: in this mode the command
described in Clause 6.6.2.5 is not generated and the set passage direction
remains open.
6.7. Operation from wireless remote control
6.5.1 Control over the turnstile with the wireless remote control is similar to that
with the remote control panel.
6.5.2 The buttons on the wireless remote control tag act the same way as those
on the RC panel.
6.5.3 The wireless remote control operation manual is supplied with that device.
6.8. Operation from an ACS controller
6.5.1 In the pulse control mode control over the turnstile from an ACS controller
is similar to that one with the RC panel.
6.5.2 In the potential control mode control over the turnstile from an ACS con-
troller is similar to that one with the RC panel and lies in forming of a low-
level signal on the contacts “Unlock A”, “Stop” and “Unlock B” relatively to
the contact “GND”.
6.5.3 The difference of the operation logic in the potential control mode com-
pared to the one in the pulse control mode (as per Clause 6.6.2): the com-
mand described in Clause 6.6.2.5 is generated only at the moment the RC
button corresponding to the passage direction
А
(
В
) is released.
Therefore to arrange single passages in the potential control mode it is
recommended to remove the control low-level signal at the beginning of the
“PASS” signal of the corresponding direction.
6.5.4 The passage through the turnstile in the
А
(
В
) direction gets registered
based on the status of the output contacts “PASS A(
В
)” and “Common”.
6.9. Optional external devices connected to the turnstile
6.9.1 The following external devices can be connected to the turnstile:
an intrusion detector and a siren;
an emergency unblocking device;
6.9.2
The intrusion detector is connected to the “XT2” connector block, and the
siren is connected to the “XT1.H” connector block of the CLB according to
the connection layout
(Fig. A.1 Appendix A and Fig. 3). The intrusion detector
should have normally closed contacts.
Note! Only the manufacturer should carry out installation of an intrusion detector
on a turnstile housing.