Operation manual
8
The control unit (CU) (8) (see Fig. 2, 3) is intended for the turnstile units powering and control. It
comes as a standalone unit in a metal case with the pull-resistant fasteners for wall mounting. The
CU can also be desk-mounted.
The CU case contains the power transformer, the DC power supplies module, the processor
module and two 12V SPS batteries.
The CU front panel (Fig. 3) contains:
•
"Power"
toggle switch (On/Off) — AC mains power-up;
•
"Battery"
toggle switch (External/Internal) — connection of the built-in SPS/external power
supply;
and the following LED indicators:
•
"Power"
– AC mains on (green);
•
"24V"
– 24V DC power supply (green);
•
"Battery"
–the CU changeover to the built-in SPS (red);
•
"24V/2A"
– 24V/2A fuse failure (red).
The CU lower panel contains:
•
fuse slot with the
“
∼
220V/1A”
fuse;
•
“Bat/2A”
fuse slot
*
;
Warning!
To avoid accidental power-up of SPS, “Bat/2A” fuse is not installed and is provided together
with the set of spare parts.
•
fuse slot with the
“=24V/2A”
fuse;
•
RC cable inlet –
“RC”
;
•
Wireless remote control cable inlet –
“Wireless”
;
•
ACS connector –
“ACS”
;
•
Control cable connector –
“Control”;
•
Power cable connector –
“DC=24V”;
•
External DC power supply connector –
“Bat = 24V”;
•
AC power cable input –
“
∼
220V”;
•
Entry for intrusion detector and siren cables –
“Alarm”.
Connections for intrusion detector and siren are given in Fig. 9).
5.3 Control over the turnstile
The turnstile can be operated:
•
from the RC;
•
from the tag of the wireless remote control kit;
•
from the ACS.
5.3.1 Control with the remote control panel
The following operating modes can be set from the RC (see Table 1):
•
always locked;
•
single passage in the set direction;
•
bidirectional single passage;
•
free passage in the set direction;
•
free passage in the set direction and single passage in the opposite direction;
•
always free.
The turnstile control with the tag of the wireless remote control kit is similar to the control with the
RC. Instruction for connection and operation of the wireless remote control kit is included in its
delivery set. Connection layout for the wireless remote control is given in Figure 9.
5.3.2 Operation from the ACS via the CU «ACS» connector
The ACS is connected to the CU «ACS» terminal with a cable (see Fig. 3). The «ACS» connector
pins assignment is shown in Fig. 4. The ACS connector (DBH15-F cable socket) is included in the
set of spare parts.
Содержание RTD-03S
Страница 1: ...OPERATION MANUAL RTD 03S Waist high Rotor Turnstile...
Страница 2: ...Waist high Rotor Turnstile RTD 03S Operation manual...
Страница 8: ...RTD 03S Waist high rotor turnstile 7 Figure 3 Control unit...
Страница 26: ...www perco com...