O
PERATING
S
OFTWARE
OS6.0
/
OS10.0
51
OUTPUT TARGET 6
Assignment of an output for the switch condition of preselection 6.
Value Designation
Function
0
NO
No assignment
1
CTRL OUT 1
Assignment of the switch condition to Ctrl. Out 1
2
CTRL OUT 2
Assignment of the switch condition to Ctrl. Out 2
3
CTRL OUT 3
Assignment of the switch condition to Ctrl. Out 3
4
CTRL OUT 4
Assignment of the switch condition to Ctrl. Out 4
5
CTRL OUT 5
Assignment of the switch condition to Ctrl. Out 5
6
CTRL OUT 6
Assignment of the switch condition to Ctrl. Out 6
OUTPUT POLARITY 6
Switch state for the switch condition of preselection 6. See PRESELECTION 1
MENU.
OUTPUT LOCK 6
Self-locking for the switch condition of preselection 6. See PRESELECTION 1
MENU.
STARTUP DELAY 6 (S)
Startup override for
the switch condition of preselection 6. See PRESELECTION
1 MENU.
4.13
Serial Menu
The default settings for the serial interface are defined in this menu.
UNIT NUMBER
This parameter can be used to set serial device addresses. The devices can be
assigned addresses between 11 and 99. Addresses that contain a "0" are not
allowed since these are used as group or collective addresses.
Value
Function
11
Smallest address without zero
…
99
Largest address without zero
Содержание K23-SSI/Rx/IU-C
Страница 1: ...Your automation our passion K23 SSI Rx IU C Signal converter Manual...
Страница 77: ...APPENDIX 77 5 6 Reading in the SSI Value The received data is always filled internally to a 32 bit data length...
Страница 79: ...APPENDIX 79 Calculating the SSI Zero Position Checking the direction of rotation Evaluating the bit suppression...
Страница 80: ...APPENDIX 80 Calculating the SSI offset Calculating the display value...
Страница 83: ...APPENDIX 83 5 8 Dimensions...
Страница 84: ...www pepperl fuchs com Subject to modifications Pepperl Fuchs Printed in Germany DOCT 6641...