BAUD RATE
Clock frequency of the SSI messages
Value Designation
Function
0
2 MHZ
N.A.
1
1.5 MHZ
N.A.
2
1 MHZ
Clock frequency 1 MHz
3
500 KHZ
Clock frequency 500 kHz
4
250 KHZ
Clock frequency 250 kHz
5
100 KHZ
Clock frequency 100 kHz
SSI ZERO
In the event of a "ZERO POSITION" command (via control input), the current SSI
position of the rotary encoder is transferred to the "SSI ZERO" parameter and the
actual rotary encoder zero point is shifted accordingly. (rotary encoder zero point
shift)
Value
Function
0
Smallest value
…
999999999
Largest value
HIGH BIT (for bit suppression)
Defines the highest bit (MSB) to be evaluated of the bit suppression.
If all bits are to be evaluated, HIGH BIT must be set to the specified total bit
number.
Value
Function
01
Smallest value
25
Default value
32
Largest value
LOW BIT (for bit suppression)
Defines the lowest bit (LSB) to be evaluated of the bit suppression.
If all bits are to be evaluated, LOW BIT must be set to "01."
Value
Function
01
Smallest value
…
32
Largest value
Содержание K23-SSI/Rx/IU-C
Страница 1: ...Your automation our passion K23 SSI Rx IU C Signal converter Manual...
Страница 77: ...APPENDIX 77 5 6 Reading in the SSI Value The received data is always filled internally to a 32 bit data length...
Страница 79: ...APPENDIX 79 Calculating the SSI Zero Position Checking the direction of rotation Evaluating the bit suppression...
Страница 80: ...APPENDIX 80 Calculating the SSI offset Calculating the display value...
Страница 83: ...APPENDIX 83 5 8 Dimensions...
Страница 84: ...www pepperl fuchs com Subject to modifications Pepperl Fuchs Printed in Germany DOCT 6641...