SAMPLING TIME (ms)
Duration between two init pulses in milliseconds. Corresponds to the time after
which a new measurement is started and directly affects the reaction time of the
device.
Value
Function
00.200
Minimum measuring time
04.000
Default value
16.000
Maximum measuring time
INIT PULSE TIME (µs)
This parameter defines the pulse duration of the init pulse in
microseconds.
Value
Function
1
Smallest value
2
Default value
9
Largest value
VELOCITY (m/s)
Waveguide velocity of the encoder used in m/s.
Value
Function
0001.00
Smallest value
2800.00
Default value
9999.99
Largest value
OPERATIONAL MODE
This parameter determines which type of measurement the device is to perform.
Value Designation
Function
0
POSITION
Distance measurement
1
ANGLE
Angle measurement
2
SPEED
Velocity measurement
Note
For more information on the different "OPERATIONAL MODES" and interpretation of
the respective measurement results, see Chapter 6.7)
Содержание K23-SSI/Rx/IU-C
Страница 1: ...Your automation our passion K23 SSI Rx IU C Signal converter Manual...
Страница 77: ...APPENDIX 77 5 6 Reading in the SSI Value The received data is always filled internally to a 32 bit data length...
Страница 79: ...APPENDIX 79 Calculating the SSI Zero Position Checking the direction of rotation Evaluating the bit suppression...
Страница 80: ...APPENDIX 80 Calculating the SSI offset Calculating the display value...
Страница 83: ...APPENDIX 83 5 8 Dimensions...
Страница 84: ...www pepperl fuchs com Subject to modifications Pepperl Fuchs Printed in Germany DOCT 6641...