Inertial Measurement Unit IMUF99*B20
Example
2
02
2-
06
31
Step 3: Leaving Parameter Mode
See also chapter "Leaving Parameter Mode"
xx: unused, bytes optional
Effect
Parameter Mode is left.
•
Sensor restarts.
•
New node ID is claimed (see also chapter "J1939 Interface Description", section "Adress
Claiming").
•
Yellow LED blinks
•
PDOs are sent
7.2
Factory reset
The following steps describe how to reset the sensor to the factory default settings:
Step 1: Starting Parameter Mode
See also chapter "Starting Parameter Mode"
xx: unused, bytes optional
Effect
Parameter Mode is started.
•
Message: D0 = Password accepted (see also chapter "J1939 Interface Description", sec
-
tion "Answer Messages").
•
Yellow LED blinks
•
No more PDOs are sent
Note
The sensor answers with the old Node-ID. New Node-ID is valid when the parameter mode is
left!
Identifier
Data Bytes
Priority
PGN
Source
address
1
CMD
2
Pass
-
word
3
4
5
6
7
8
0x00
0xEF80
0x01
0xEB
0x00
xx
xx
xx
xx
xx
xx
Table 7.3
Identifier
Data Bytes
Priority
PGN
Source
address
1
CMD
2
Pass
-
word
3
4
5
6
7
8
0x00 0xEF80
0x01
0xEB
(CMD:
Start
param
-
eter
mode)
0x55
xx
xx
xx
xx
xx
xx
Table 7.4