2
02
1-
09
26
Functional Safety K-LB-*.*, F*-LB-I, P-LB-*.*.*
Operation
Resistance Measurement
Device
Step no.
Rated voltage
Comment
P-LB-1.A.13
1
2
Resistance between Pins 1, (1)
Resistance between Pins 3, (3)
Test passed if resistance
is below 2
.
P-LB-2.A.1346
1
2
3
4
Resistance between Pins 1, (1)
Resistance between Pins 3, (3)
Resistance between Pins 4, (4)
Resistance between Pins 6, (6)
Test passed if resistance
is below 2
.
P-LB-1.B.12
1
2
Resistance between Pins 1, (1)
Resistance between Pins 2, (2)
Test passed if resistance
is below 2
.
P-LB-2.B.1245
1
2
3
4
Resistance between Pins 1, (1)
Resistance between Pins 2, (2)
Resistance between Pins 4, (4)
Resistance between Pins 5, (5)
Test passed if resistance
is below 2
.
P-LB-1.C.123
1
2
3
Resistance between Pins 1, (1)
Resistance between Pins 2, (2)
Resistance between Pins 3, (3)
Test passed if resistance
is below 2
.
P-LB-2.D.123456 1
2
3
4
5
6
Resistance between Pins 1, (1)
Resistance between Pins 2, (2)
Resistance between Pins 3, (3)
Resistance between Pins 4, (4)
Resistance between Pins 5, (5)
Resistance between Pins 6, (6)
Test passed if resistance
is below 2
.
P-LB-1.E.23
1
2
Resistance between Pins 2, (2)
Resistance between Pins 3, (3)
Test passed if resistance
is below 2
.
P-LB-2.C.2356
1
2
3
4
Resistance between Pins 2, (2)
Resistance between Pins 3, (3)
Resistance between Pins 5, (5)
Resistance between Pins 5, (5)
Test passed if resistance
is below 2
.
P-LB-1.D.1234
1
2
3
4
Resistance between Pins 1, (1)
Resistance between Pins 2, (2)
Resistance between Pins 3, (3)
Resistance between Pins 4, (4)
Test passed if resistance
is below 2
.
P-LB-1.F.1236
1
2
3
4
Resistance between Pins 1, (1)
Resistance between Pins 2, (2)
Resistance between Pins 3, (3)
Resistance between Pins 6, (6)
Test passed if resistance
is below 2
.
Table 5.6