76700 -65/94-
23-4. Procedure of adjustment
(1) Connect the AC adaptor to the camera.
(2) Connect the camera to the computer by the USB cable
(3) Attach the Master lens to camera while confirming the aperture of Master lens is set to F8.
(4) Turn the main switch ON, and then confirm that the camera is recognized as a [Removable
Disk] under [My Computer]
(5) Set the camera and master lens toward center of light window of LB3300, and then cover the
whole camera by using a dark curtain and so on.
(6)
Start the adjustment software (CSAdjust.exe). Input ID number of master lens and then click
OK button.
[CAUTION] The adjustment software ends compulsorily while indicating the following error
message if ID number which is not correct is input and OK button is clicked. In that case, restart
the adjustment software and then input correct ID.
■
Lens ID No. Input display
■
Error display
(7) The following window will be displayed when the adjustment software is started.
Wait for 20 seconds
Содержание K 100D Super
Страница 1: ...PENTAX Service Co Ltd Technical Service Dep Product No 76700 TM 仮サービスマニュアル TM TM ...
Страница 5: ...76700 4 94 Click OK Do not click Directory Click installation button ...
Страница 6: ...76700 5 94 Set up will be started Click OK to end the installation ...
Страница 49: ...76700 48 94 6 A74 TYscrew x2 5 5mm 7 Close SD card cover 6 7 ...
Страница 84: ...76700 83 94 Block diagram ...
Страница 86: ...76700 85 94 AE Program line normal and APEX chart ISO200 Standard program exposure mode DA F 3 5 5 6 18 55mm ...