76700 -25/94-
7
.
0-S300
①
Arrange the lead wires from motor as shown
Figure and then attach 0-S300
②
TY-CNL-D1.7x3.5
③
TY-CNL-D1.7x5.5
④
Install S364 as shown in a figure.
⑤
Apply screw lock
⑥
A115
⑦
TY-CNL-G1.7x2.5
8.
【
ADJ
】
AF Joint stroke
[Required equipment] Vernier calipers
①
Set the AF lever to the AF position
②
AF coupler(0-S300) must be projected from the mount surface by 1.2mm or more.
③
When the mount lock pin comes to the mount surface with depressing the mount lock lever,
the AF coupler must not be projected out of the mount surface.
④
Adjustment- 0-A121 by turning an eccentric screw, and apply the screw lock
S364
0-S300
①
②
③
⑦
⑤
⑥
SL
④
①
②
③
SL
④