76700 -50/94-
(9)
18.0-A301 (Top cover)
*Befor installing 0-A301, confirm installed condition for parts.
*There is no bent for Main SW contact and confirm that the contact is the same hight.
(1) Apply G151 to land of Main SW contact.
(2) Confirm that the land for Main SW on T200 is not shorted by solder.
(3) Put top cover to body.
(4) Solder 3 lead wires. (Pink, Purple, Black)
(5) Pop-up Flash for installing screw.
(6) Arrange 3 lead wires between body and top cover, then attach
top cover to the body without pinching lead wires.
(7) Connect T51 Flex + Fold Excess Flex under Top cover
(8) A73 (TY screw x2, 4.5mm)
(9) A73 (TY screw)
(10) A74 (TY screw x2, 5.5mm)
(11)TY-CNL-D1.7x8.0 (Battery chamber)
(8)
(7)
(10)
(1)
G151
(5)
(2) Main SW
Land
(4) Pink
Purple
Black
(A330)
(3)
Содержание K 100D Super
Страница 1: ...PENTAX Service Co Ltd Technical Service Dep Product No 76700 TM 仮サービスマニュアル TM TM ...
Страница 5: ...76700 4 94 Click OK Do not click Directory Click installation button ...
Страница 6: ...76700 5 94 Set up will be started Click OK to end the installation ...
Страница 49: ...76700 48 94 6 A74 TYscrew x2 5 5mm 7 Close SD card cover 6 7 ...
Страница 84: ...76700 83 94 Block diagram ...
Страница 86: ...76700 85 94 AE Program line normal and APEX chart ISO200 Standard program exposure mode DA F 3 5 5 6 18 55mm ...