76700 -37/94-
11. 0-C000 (CCD/SR block)
*To prevent the damage of SI-LED, attach mount cover. Then put downward.
[Caution] CCD/SR block has strong magnet inside threrfore, caution for adsorption of parts.
[Caution] There is no dust, no scratch on surface of CCD
(1) [Confirm] Center plate must move up and down and right and left by own weight.
(2) Install CCD/SR block according to the guide pin of the plate
(3) C45 Screw (Stainless-steel, x3)
(2)
(1)
[Caution] When replacing 0-C000:
1. Arrange the flex as shown figure. Do not bend he flex
2. Peel off the tape attached on the buttom plate and replace new CCD ID No. seal of C000.
* Number must readable.
Содержание K 100D Super
Страница 1: ...PENTAX Service Co Ltd Technical Service Dep Product No 76700 TM 仮サービスマニュアル TM TM ...
Страница 5: ...76700 4 94 Click OK Do not click Directory Click installation button ...
Страница 6: ...76700 5 94 Set up will be started Click OK to end the installation ...
Страница 49: ...76700 48 94 6 A74 TYscrew x2 5 5mm 7 Close SD card cover 6 7 ...
Страница 84: ...76700 83 94 Block diagram ...
Страница 86: ...76700 85 94 AE Program line normal and APEX chart ISO200 Standard program exposure mode DA F 3 5 5 6 18 55mm ...