76700 -24/94-
6.
【
ADJ
】
Positioning 1
st
and 2
nd
Mirror
[Required equipment] 1
st
mirror angle (45°) adjusting jig, Mirror angle adjusting jig for 27830,
Mirror positioning scope.
*
Adjustment is performed by turning B58 (2 pcs). The Y-axis (the vertical direction) is adjusted
to a 0 target.
*
Front housing must set mirror down position.
①
Positioning 1 st mirror : Put the 1
st
mirror angle (45°) adjusting jig on the camera,
and then adjust the mirror seat so that the adjusting jig touches the mirror without gap.
Tolerance ---- X-axis : ±15’
Y-axis : ±10’
②
Positioning 2
nd
mirror : Attach the mirror positioning scope and the
2
nd
mirror angle adjusting jig to the camea, and then adjust the
mirror angle while looking through the eyepiece lens.
Tolerance ---- X-axis : ±0.3mm
Y-axis : ±0.1mm
(Refer to below tolerance for positioning scope)
③
After adjustment is done, apply the supper-glue to both B58.
■
Tolerance for 2
nd
mirror position
(Using with the mirror positioning scope)
1st mirror
B58
2nd mirror
1mm hole
OK
OK
NG NG
(
Standard
)
Scale
Center of Standard
1
2
-
2
-
1
2
1
-
1
-
2
1
2
-
2
- 1
2
1
- 1
- 2
NG: 0.8(X) or over
NG: 0.6(Y) or over
:
Tolerance of 1 mm hole
(
X-axis=±0.6
、
Y-axis=±0.8
)
Содержание K 100D Super
Страница 1: ...PENTAX Service Co Ltd Technical Service Dep Product No 76700 TM 仮サービスマニュアル TM TM ...
Страница 5: ...76700 4 94 Click OK Do not click Directory Click installation button ...
Страница 6: ...76700 5 94 Set up will be started Click OK to end the installation ...
Страница 49: ...76700 48 94 6 A74 TYscrew x2 5 5mm 7 Close SD card cover 6 7 ...
Страница 84: ...76700 83 94 Block diagram ...
Страница 86: ...76700 85 94 AE Program line normal and APEX chart ISO200 Standard program exposure mode DA F 3 5 5 6 18 55mm ...