76700 -32/94-
3. Front housing
(1) Apply DC 2V to the mirror motor, and set mirror up position.
(Red --- +)
(2) To prevent the damage of SI-LED, attach mount cover. Then put downward.
(3) Attach body plate to the mirror housing.
* Pay attention the lead wires and flex.
(4) TY-CNM2.0x5.0 (x5)
(5) Apply DC2V to the mirror motor, and set mirror down position.
[Caution] Do not make scratch on the eyepiece lens while working.
4.0-Q200 (Flash PCB)
(1) 0-Q200 Arrange the lead wires as shown figure.
*Avoid pinching lead wire.
(2) TY-CNL-D1.7x4.0 (x2)
(3) A5 (A4/A15)
*Arrange Gray lead wire at the back
(4) CNL-D1.7x2.5
(5) TY-CNL-D1.7x4.0
(2)
(3)
(5)
(4)
(1)
(5)
(4)
(3)
(2)
(1)