76700 -21/94-
⑲
0-G100
----Surely install G100 without any gap between plate.
⑳
TY-CNL-D1.7x3.0
(
x4
)
【
Arrangement when replace G100
】
1.
Arrange the lead wires with DT(5x15) as shown in figure
2.
Solder 4 lead wires.
3.
Two lead lines are passed through S364
⑳
⑲
DT(5x15)
Pink (45mm)
Purple (40)
Red (80mm)
Black (80)
[Notice for Disassembly] Set the mirror seat at top position before removing 0-G100.
1.
As shown in a figure, a gear is turned, and it sets to a mirror up position.
[Caution] Since there is no stopper B65 of a mirror, don't carry out by turning on electricity to a
mirror motor absolutely.
Mirror up: (Shutter charge lever(1) and mirror seat(2) and sliding plate(3) must be top end
position. )
2. Latch the lever of G100 while pushing down the sliding plate.
②
③
①